GENERAL RULES FOR INSTALLATION
This book lists the wiring diagrams of the most common installations. The following gene-
ral rules are valid for each type of installation.
1)
Carry out installation of conductors on the appropriate tubing excluding the passage
of Mains, light and industrial wires. It is advisable to use conductors which are diffe-
rently coloured in order to facilitate the connection.
2)
The equipment must be installed in a dry place far from any source of heat.
3)
Once the connections have been carried out, make sure that the insertion to the
Mains voltage is correct. Check that all the handsets are hooked, before proceeding
with the general test and inspection. Adjust the volume and the connection time
whenever needed.
4)
To operate electric locks at the same time, in connections with very long lines, use a
repeater relay Art. 170/001. This relay must be used for operation with a higher vol-
tage. (125-230V) as, for example, to turn on hall and stair lights.
N.B. We recommend that the instructions of every diagram are carefully followed and
that the sections of the conductors compared to the distances are respected.
MINIMUM CONDUCTOR SECTION FOR AUDIO DOOR ENTRY
SYSTEM (mm
2
)
Conductors Ø up to 50 m.
Common
and lock
0.5 mm
Other
0.25 mm
MINIMUM CONDUCTOR SECTION FOR VIDEO-DOOR ENTRY
SYSTEM (mm
2
)
Terminals
Ø up to 50 m.
- + Lock
+T C1 C2
1 mm
Other
0,75 mm
Video
75 Ohm coaxial cable (type RG59) or RG11
double insulation
Conversion table for section-diameter and resistance of 100 m. standard
conductors.
Section mm 2
Diameter mm.
Diameter (tenths)
Resistance Ω 100m.
SYMBOLS
A.C. bell
A.C. buzzer
Electric lock
4
Ø up to 100 m.
2
2
0.75 mm
2
2
0.5 mm
Ø up to 100 m.
2
2
1,5 mm
2
2
1 mm
0.12
0.25
0.35
0.50
0.40
0.58
0.68
0.80
4/10
6/10
8/10
14.00
6.60
4.80
3.50
Bulb
Push-button
Switch
Ø up to 200 m.
2
1.5 mm
2
1 mm
Ø up to 200 m.
2
2,5 mm
2
1,5 mm
0.75
1.00
1.50
2.50
1.00
1.15
1.40
1.80
10/10
12/10
14/10
18/10
2.20
1.70
1.14
0.69
Loudspeaker
Amplified microphone
Receiver
SAFETY INSTRUCTIONS FOR INSTALLERS
- Carefully read the instructions on this leaflet:
they give important information on the safety,
use and maintenance of the installation.
- After removing the packing, check the integrity of
the set. Packing components (plastic bags,
expanded polystyrene etc.) are dangerous for
children. Installation must be carried out accord-
ing to national safety regulations.
- It is convenient to fit close to the supply voltage
source a proper bipolar type switch with 3 mm
separation (minimum) between contacts.
- Before connecting the set, ensure that the data
on the label correspond to those of the network.
- Use this set only for the purposes designed,
i.e.for electric door-opener systems. Any other
use may be dangerous. The manufacturer is not
responsible for damage caused by improper,
erroneous or irrational use.
- Before cleaning or maintenance, disconnect the
set.
- In case of failure or faulty operation, disconnect
the set and do not open it.
- For repairs apply only to the technical assistance
centre authorized by the manufacturer.
- Safety may be compromised if these instructions
are disregarded.
- Do not obstruct opening of ventilation or heat
exit slots and do not expose the set to dripping
or sprinkling of water.
- Installers must ensure that manuals with the
above instructions are left on connected units
after installation, for users' information.
- All items must only be used for the purposes
designed.
- This leaflet must always be enclosed with the
equipment.
4.00
6.00
2.30
2.80
0.39
0.28
A.C. supply from mains
Ground
Coaxial cable block