1.0 mm²max.12.5 m
1.5mm²max.20 m
2.5mm² max.30 m
Power cord connections should be kept dry and off the ground.
•
If the power cord is damaged, it must be replaced by the manufacturer or his service agent or similarly
qualified person in order to avoid a hazard.
• All keep the machine on a stable and flat surface during operation, handling, transportation and storage.
Sudden overturn of machine will cause injury to body.
• In the event of accident or breakdown, switch off the machine immediately. (e.g. contact with deter-
gent: rinse with an abundance of clean water)
Attention!
Through poor conditions of the electrical MAINS, shortly voltage drops can appear when starting the EQUIP-
MENT. This can influence other equipment (eg. Blinking of a lamp).
If the MAINS-IMPEDANCE Zmax< 0.335 OHM, such disturbances are not expected. (In case of need, you may
contact your local supply authority for further information.)
WARNING! Electrical Shock Hazard
Improper connection of the equipment-grounding conductor can result in a risk of electrical shock. Check
with a qualified electrician or service person if you are unsure if an outlet is properly grounded.
DO NOT modify the plug provided with the appliance to fit an outlet, have a proper outlet installed by a
qualified electrician.
Mains power connection
The following should be observed when connecting the high pressure washer to the electric installation:
• The electric installation shall be made by a certified electrician and comply withIEC-364.
• It is recommended that the electric supply to this appliance should include either a residual current de-
vice that will interrupt the supply if the leakage current to earth exceeds 30 mA for 30 cm.
IMPORTANT!
Only use water without any impurities.
If there is a risk of running sands in the inlet water (i.e. from your own well), an additional filter should be
mounted.