Led-Signals - CAME MR8534 Manual Del Instalacion

Detector de seguridad
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 17

LED-SIGNALS

The RED or GREEN
LED is ON sporadicly
or permanently.
The sensor does not
react, but a calibration
can be launched.
The ORANGE LED is
on permanently.
The ORANGE LED
fl ashes quickly.
The ORANGE LED
fl ashes 1 x
1
every 3 seconds.
The ORANGE LED
fl ashes 2 x
2
every 3 seconds.
The ORANGE LED
fl ashes 3 x
3
every 3 seconds.
The ORANGE LED
fl ashes 4 x
4
every 3 seconds.
The ORANGE LED
fl ashes 5 x
5
every 3 seconds.
 
SAFETY INSTRUCTIONS
The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system
in compliance with applicable national and international regulations and standards on door safety and if applicable, the machinery directive 2006/42/EC.
Only trained and qualifi ed personnel may install and setup the sensor. The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel. Avoid
touching any electronic and optical components.
Came S.p.A.- Via Martiri Della Liberta 15 - IT-31030 DOSSON DI CASIER (TV)
TEL (+39) 0422 4940 - FAX (+39) 0422 4941 - info@came.it - www.came.it
CAME hereby declares that MR8534/MR8570/MR8590 is in conformity with the basic requirements and the other
relevant provisions of the directives 1999/5/EC, 2004/108/EC and 2006/42/CE.
Only for EC countries: According to the European Guideline 2002/96/EC for Waste Electrical and Electronic Equipment
(WEEE)
Original upon request.
-
BUY
TO
Bad calibration
Bad adjustment of the
uncovered zone.
The sensor is disturbed by
lamps or another sensor.
The monitoring is activated,
but the test input is not
powered.
The sensor encounters a
memory problem.
DIP-switch setting
awaiting confi rmation.
The sensor signals an
internal fault.
Power supply is out of limit.
Communication error
between modules.
The sensor receives
not enough IR-energy.
Calibration error
-
SELL PRODUCT
1
Launch a calibration.
1
Check if the DIP-switch 4 is in correct position.
2
Launch a calibration.
1
Select a different frequency for each module (DIP 2).
Launch a calibration.
2
Chech wiring.
1
- Door control with test:
Connect RED and BLUE wires to test output.
- Door control without test:
Connect BLUE to 0 V and RED to +12 V - 30 V DC.
1
Send the sensor back for a technical check-up.
Corfi rm the DIP-switch setting:
1
long push on the push button.
1
Cut and restore power supply.
If orange LED fl ashes again, replace sensor.
2
1
Check power supply (tension, capacity).
2
Reduce the cable length or change cable.
Check wiring between modules.
1
Launch a module count: long push on push button
2
of MASTER.
1
Launch a new calibration.
2
Step out of the detection fi eld.
3
Change angle of spots.
Switch off background (DIP 3: OFF).
4
Check mounting height.
1
Change position of calibration screw.
2
Launch a new calibration.
3
Switch off background (DIP3: OFF)
4

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mr8570Mr8590

Tabla de contenido