Air Curtain Owner's Manual
1 Working principle
The air of indoor sucked in by the cross flow fan of the air curtain, blown down to the floor at a high
speed. And the downward airflow formed an invisible"wall".
The air curtain is usually installed on the upside of the door the window, when the door or the window
is opened, the airflow of the air curtain could isolate the air of the indoor side and outdoor side effectively.
Thus the cool air leaking of the indoor side can be reduced, and can prevent the mosquitoes and dust from
entering into the room as well.
The length of air curtain should be consonance with the width of the door or the window, put two sets
of unit or more side by side to cover the width of the door or window entirely.
In order to obtain more effective efficiency, the air outer of the air curtain should be paralleled with the
door head, ensure that the speed of airflow which arrived at the floor should be more than 2.5meters/sec.
2 Specification
Length
Diameter of
Model
Power supply
(mm)
impeller(mm)
220-240V~
FM-1.25-9-K
900
125
50Hz/60Hz
220-240V~
FM-1.25-12-K
1200
125
50Hz/60Hz
220-240V~
FM-1.25-15-K
1500
125
50Hz/60Hz
3 Installation
The installing location should be firm enough, free of vibration. The unit cannot be installed in the damp
or the water-leaking place and should avoid the directly lighting of sunlight.
Installation method:
(1) Take out the wall-mounted frame, put it attach to the wall, to confirm the installation position of the
bolt hole and to make the mark on it.
(2) To drill the expansion bolt hole on the marked position.
(3) To fix the wall-mounted frame on the wall with 8pcs M10 expansion bolt, the installation must be
firm and reliable.
(4) Hang the unit on the wall-mounted frame, and screw down the 4pcs bolt under the unit.
(5) To check whether the unit is well installed, the body level and pluged in.
(6) The dimension diagram for hole position of wall-mounted frame was shown in below (Unit:mm):
Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.
Power
Noise
Weigh
W×D×H
input(W)
dB(A)
(kg)
(mm×mm×mm)
110
59
16
900×206×215
140
61
20
1200×206×215
180
61
25
1500 X206X215
-1-
Model
A
FM-1.25-9-K
160
FM-1.25-12-K
160
FM-1.25-15-K
160
Notes:
(1) Please install unit on the indoor side.
(2) Do not install or use the unit in place where:
1) Freezing may occur.
2) Steam is produced.
3) Remarkable dust is produced.
4) Oil smoke is produced.
5) Explosive dust or gas exist.
6) Corrosive gas is produced.
7) It is splashed by water.
(3) Please install the unit horizontally, make the air outlet downward vertically.
(4) Install the unit in sturdy place free of vibration.
(5) In order to prevent accident of electric shock, make sure that earthed well.
(6) Provide an electric leakage breaker and air-break switch should be installed at the power supply
side.
(7) The Air Curtain is to be installed so that the blades are more than 2.3m above the floor.
(8) The place where the AIR CURTAIN is to be installed must be taken to avoid the black flow of gases
into the room from the open flue of gas or other fuel-burning appliance.
(9) It is necessary to have the plug accessible after installation.
(10) The minimum distance between the various parts of the appliance and the surrounding structure is
300mm.
4 Circuit diagram
Power:220-230V~ 50/60Hz
BN(BK)
L
BU(WH)
N
YE/GN(GN)
PE
BK
BU
WH
YE/GN
BN
E
C
FAN MOTOR
RD
B
800
1100
1400
AC-L
AC-N
TC
POWER TRANSFORMER
AP2
FAN-H
FAN-L
AP1
AC-N
-2-
C
870
1170
1470