Installation
1. Disconnect the power source.
2. Use the security hex key supplied to turn the cover mounting screws clockwise to remove the cover from the dryer.
3. Place the hand dryer base on the wall at the desired location using Table 2 to determine the recommended mounting height. With
the base so located, use it as a template to mark locations of the 4 mounting bolt holes on the wall. Ensure that no reflective object
(such as a hand basin) is located directly under infra-red sensor eye; the minimum distance is 18" (46 cm).
4. Fasten the base to the wall, using the type of bolts suggested in Table 3.
5. All automatic dryers must have their own dedicated 10 amp circuit.
6. Connect the dryer to the nearest suitable distribution panel.
7. Replace cover, turn screws counter-clockwise making certain not to over-tighten.
IMPORTANT: Consult local and general regulations before performing dryer installation. Ensure that the electrical
network is not overloaded. Do not connect to a branch circuit over 10 amps.
Table 2
Recommended Mounting Heights from Floor to Dryer Bottom Edge
Men's washrooms
Women's washrooms
Children's washrooms, ages 4-7
Children's washrooms, ages 7-10
Children's washrooms, ages 10-13
Children's washrooms, ages 13-17
Handicap Mounting Height
Table 3
Type of Wall
Hollow Tile, Lath, Wall Board or Metal
Cement, Brick, or Tile Covered Cement or Brick
Stud Wall with wood Backing
Maintenance and Cleaning Instructions
Maintenance
1. Remove fuse or shut off power to the dryer at fuse box.
2. With Allen wrench supplied with dryer, turn clockwise two Allen screws from bottom side of dryer case.
3. Remove dryer cover.
Cleaning Instructions
Read complete instruction before proceeding. Under normal use, cleaning the Dryer once a year will keep it in good operating condition.
If the washroom traffic is heavier than normal, the cleaning should be done every 6 months. Lint and dust build up inside the dryer can
result in damage to motor.
1. Turn off dryer at circuit breaker or fuse panel.
2. Turn clockwise two cover mounting screws from dryer cover using security hex key provided. Support cover while removing screws.
3. Vacuum out dirt from blower and housing. Use caution not to damage wires or circuit boards.
4. The motor inlet cover may be removed by unscrewing the (4) screws. This allows access to the motor for cleaning or replacement.
5. Use soft-medium bristle ½" paint brush to clean dust and dirt from motor.
6. Replace cover. Place cover squarely over base and push flush to wall. Turn cover mounting screws counter-clockwise and tighten
until snug. Do not over tighten.
Form No. DR-570
68-10218 rev02
Multi Language
(Rev. 3/14/14)
Type of Bolt
1/4" (M6) screw Type or Wing Type toggle
Bolts
1/4" (M6) Stud Type Expansion Bolts
No 16 (M8) Wood Screws
© 2014 Gamco Commercial Restroom Accessories, A Division of Bobrick
5
in. (cm.)
46" (117)
44" (112)
32" (81)
36" (91)
40" (102)
44" (112)
37" (94)
Minimum Bolt Length
Dependent on wall thickness
3"
(76mm)
2-3/4" (70mm)
Printed in U.S.A.