INSTALLING THE POWERPLUG RECEPTACLE WITH RUBBER WASHER
It is important for the powerplug receptacle to be flush with the ceiling surface. Outlet boxes are typically
not even with the surface or sheet rock and the rubber washers will help to reduce or eliminate the gap.
Follow these instructions. The washer size is marked on the bag.
Fig 1.
Fig 2.
Fig 3.
10
Fan Installation
4mm rubber w asher
7mm rubber washer
4mm rubber washer
7mm rubber washer
Fig 1. Outlet box is flush with the ceiling or the
gap is less than 1.5mm, use 4mm rubber washer
provided. Place the washer above the powerplug
receptacle as shown.
0-1.5mm
Fig 2. Outlet box and ceiling with gap is more than
1.5mm but less than 3mm, use the 7mm rubber
washer provided. Place the washer above the
powerplug receptacle as shown.
1.5-3mm
Fig 3. Outlet box and the ceiling with gap from
3mm to 5mm, use both 4mm and 7mm rubber
washers provided. Place the washer above the
powerplug receptacle as shown.
>3mm