Technical data
Type
Order no.
Subscriber connections
Inputs
Frequency range
Through loss
Connection loss (terrestrial)
Gain to the subscriber connection (SAT)
Adjustable attenuator setting range (SAT, 1 dB steps)
Horizontal/vertical decoupling
Trunk decoupling
Operating level ²
)
Subscriber frequency/SCR address
Screening factor
Permissible supply voltage at the subscriber output
Max. power consumption multi-switch
Nominal input voltage
Nominal input power (at 800/200/0 mA load)
Secondary voltage (input horiz. low)
Max. total remote feed current
Max. remote feed current per trunk
Protection class/protection type
Ambient temperature range
Connections
Dimensions
Packaging unit/weight
1)
Frequency-dependent attenuation/gain (pre-emphasis)
With 15 dB attenuation the operating level decreases to 78 dBμV
2)
Via horizontal low input
3)
1)
Receiver 1
Receiver 2
Receiver 3
Receiver 4
Receiver 5
Receiver 6
Receiver 7
Receiver 8
3)
EXR 1581
20510032
1 x 8
1 x terrestrial
4 x Sat IF
MHz
5-862
950-2150
dB
-
dB
1
dB
-
dB
-
dB
-
dB
-
dBμV
-
1284/0
1400/1
1516/2
MHz
1632/3
1748/4
1864/5
1980/6
2096/7
5-300 MHz > 85; 300-470 MHz > 80
dB
470-1000 MHz > 75; 1000-2400 MHz > 55
V
12-14
mA
240
V
198-253
W
18,1/5/1,5
V
18
mA
800
mA
-
II (insulated)/IP 30
°C
- 20 to + 55
F connectors
mm
215 x 148 x 43
pc./kg
1 (10)/0.65
EXR 2581
20510033
1 x 8
1 x terrestrial
5-862
-
2.5
-
7
7 → 12
-
0-15
-
30
-
-
-
93
-
1284/0
1400/1
1516/2
1632/3
1748/4
1864/5
1980/6
2096/7
12-14
240
-
-
-
-
1000
IP 30
- 20 to + 55
F connectors
160 x 148 x 43
1 (10)/0.45
4 x Sat IF
950-2150
2.0
-
7 → 12
0-15
30
40
93