4.6 Decimal point
The decimal point indicates the
number of decimal places.
0
0.0 one decimal place
0.00 two decimal places
0.000 three decimal places
0.0000 four decimal places
4.7 Min. input signal (only if input
signal range is 4..20 mA or 2..10 V)
This menu item allows a limitation of the display
range (refer to 4.9 and 9.4)
a) or b) is selected depending
on the chosen input range
a)
If, with the input range 4..20
mA, the input signal level beco-
mes smaller than this value, the
display shows „lo".
If, with the input range 2..10 V,
b)
the input signal level becomes
smaller than this value, the dis-
play shows „lo".
4.8 Displayed value at min. input signal
A corresponding display value
between -19999 and 99999 can
be assigned to the lowest input
signal. The decimal point posi-
tion is considered.
4.9 Max. input signal (only if input
signal range is 4..20 mA or 2..10 V)
This menu title allows a limitation of the display
range (refrt to 4.7 and 9.4)
a) or b) is selected depending
on the chosen input range
If, with the input range 4..20
a)
mA, the input signal level
exceeds this value, the display
shows „hi".
If, with the input range 2..10 V,
the input signal level exceeds
this value, the display shows
b)
„hi".
3
no decimal place
4.10 Displayed value at max. input signal
A corresponding display value
between -19999 and 99999 can
be assigned to the highest
input signal. The decimal point
position is considered.
4.11 End of programming
Programming routine will be
passed through once again. All
parameters can be checked.
Programming routine will be left
and the new parameters will be
stored. Afterwards the device is
ready to use.
5. Connections
1 10 – 30 VDC
2 GND
3 GND
4 LATCH
5 0 (4) – 20 mA
6 Analogue GND
7 0 (2) –10 V DC
6. Technical data
Display:
5-digit 7-segment red
LED-Display,
8 mm high characters
Range of input signals
0 .. 10 V DC
2 .. 10 V DC
0 .. 20 mA DC
4 .. 20 mA DC
Resolution:
14 bits
Linearity:
< 0.1% ± 1 digit at an ambi-
ent temperature of 20 °C
Zero adjustment: automatic
Temperature drift:
<70ppm/K
Measuring rate: 0.5 Measurement/sec ...
2 Measurements/sec
Current measurement:
Voltage drop:
max. 2.0 V at 20 mA
Current limitation: 50 mA