Kohler K-2972 Guia Del Usuario página 7

Ocultar thumbs Ver también para K-2972:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Check the Temperature Setting
NOTE: The thermostatic valve cartridge is calibrated at the factory
for a shower temperature of approximately 104°F (40°C) to 105°F
(41°C) and a maximum hot temperature of 120°F (49°C).
Turn the water on.
Attach a trim handle or plaster guard (found in volume control
valve K-2974 or K-2977 or transfer valve K-728), onto the valve
spline adapter.
Turn the valve spline adapter fully counterclockwise so the trim
handle or plaster guard can no longer move. The valve spline
adapter is now in the full hot position.
Allow the water to run for several minutes to stabilize the water
supply temperatures.
Position a thermometer in the water stream to check the
temperature of the hot water.
If the water temperature exceeds 120°F (49°C) or is less than
desired, proceed to the "Adjust the Hot Temperature Limit"
section.
Turn the trim handle or plaster guard clockwise until you hear a
click. Do not turn any further. This is the shower temperature
position.
Remove the trim handle or plaster guard from the valve spline
adapter.
Kohler Co.
Increase Temperature
Spline
Adapter
Decrease Temperature
7
1145568-5-A

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

K-2975K-2973K-2976

Tabla de contenido