St Switch Indicator Lights - Westinghouse ST Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

OPERATION
WHEN UTILITY POWER COMES BACK ON:
After an outage when utility power returns the ST Switch will run a quick diagnostic to confirm there are no spikes
or flickering in the utility power before transferring input power back to utility. Once utility is returned the red utility
loss indicator light will turn off and the utility and generator power indicator lights will remain on. After power has
been transfered back to utility power, the ST Switch will allow the generator 45-50 seconds to cool down before
shutting it off. Once the generator has shut down the green generator power indicator light will turn off.
NOTE: If utility power is lost during the generator cool down phase the ST Switch will wait a couple of seconds and
transfer input power back to generator power until utility power is restored.

ST SWITCH INDICATOR LIGHTS

Lights Displayed Description
Input power for appliances plugged into the ST Switch is being
provided by utility power.
Utility power has been lost and there is no power being provided to
appliances plugged into the ST Switch. In 5-10 seconds of this light
being on the ST Switch will turn the generator on.
Utility power is off and power to appliances plugged into the ST
Switch is being provided by generator.
Utility power has come back on but ST Switch is running diagnostic
to make sure power is steady before transferring. This diagnostic
usually takes 5-10 seconds and then the red utility loss light should
turn off.
Generator is in cool down stages before shutting off. This takes 45-
50 seconds after the red utility loss indicator turns off.
13

Publicidad

Tabla de contenido
loading

Tabla de contenido