FAN/LIGHT
COMBINATION VENTILATORS
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OB-
SERVE THE FOLLOWING:
1. Use this unit only in the manner intended by
the manufacturer. If you have questions, con-
tact the manufacturer at the address or tele-
phone number listed in the warranty.
2. Before servicing or cleaning unit, switch
power off at service panel and lock the ser-
vice disconnecting means to prevent power
from being switched on accidentally. When
the service disconnecting means cannot be
locked, securely fasten a prominent warn-
ing device, such as a tag, to the service
panel.
3. Installation work and electrical wiring must
be done by a qualified person(s) in accor-
dance with all applicable codes and stan-
dards, including fire-rated construction
codes and standards.
4. Sufficient air is needed for proper combus-
tion and exhausting of gases through the
flue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating
equipment manufacturer's guideline and
safety standards such as those published
by the National Fire Protection Association
(NFPA), and the American Society for Heat-
ing, Refrigeration and Air Conditioning En-
gineers (ASHRAE), and the local code au-
thorities.
5. When cutting or drilling into wall or ceiling,
do not damage electrical wiring and other
hidden utilities.
6. Ducted fans must always be vented to the
outdoors.
7. If this unit is to be installed over a tub or
shower, it must be marked as appropriate
for the application and be connected to a
GFCI (Ground Fault Circuit Interrupter) - pro-
tected branch circuit.
8. Never place a switch where it can be
reached from a tub or shower.
9. This unit must be grounded.
!
CAUTION
1. For general ventilating use only. Do not use
to exhaust hazardous or explosive materi-
als and vapors.
2. This product is designed for ceiling installa-
tion only. This product is designed for instal-
lation in ceilings up to a 12/12 pitch.
Ductwork must point up. DO NOT MOUNT
THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy
and/or unbalanced impellers, keep drywall
spray, construction dust, etc. off power unit.
3. Please read specification label on product
for further information and requirements.
®
TYPICAL INSTALLATIONS
POWER CABLE
CEILING
JOIST
CEILING
MATERIAL
HOUSING MOUNTED
DIRECTLY TO JOIST
2x6 (or larger)
Discharge parallel to joists.
POWER CABLE
2 x 4
CEILING
JOIST or
TRUSS
CEILING
MATERIAL
HOUSING MOUNTED
Requires additional framing
for mounting tabs.
Discharge parallel to joists.
POWER CABLE
" "
CEILING
JOIST
MATERIAL
HOUSING MOUNTED TO "I" JOIST
Requires additional framing
for mounting tabs.
Discharge parallel to joists.
Additional framing must be a 2x6 (minimum height), at least 9-inches long.
*
Installer: Leave this manual with the homeowner.
Homeowner: Use and Care information on page 4.
MODELS 678 • 678MX • 679 • 680 • 679FL • 680FL
MOUNTING TABS
HOUSING
GRILLE
ADDITIONAL
MOUNTING
FRAMING
*
TABS
2 x 4
CEILING
JOIST or
TRUSS
HOUSING
GRILLE
TO 2x4 TRUSS
ADDITIONAL
FRAMING
*
MOUNTING
TABS
HOUSING
" "
JOIST
GRILLE
4" ROUND
DUCT
POWER CABLE
MOUNTING TABS
HOUSING
ADDITIONAL
CEILING
FRAMING
MATERIAL
GRILLE
HOUSING MOUNTED
TO ADDITIONAL FRAMING
Discharge 90
0
to joists.
4" ROUND
DUCT
POWER CABLE
MOUNTING TABS
HOUSING
ADDITIONAL
2 x 4
CEILING
FRAMING
CEILING
GRILLE
MATERIAL
JOIST or
TRUSS
HOUSING MOUNTED TO 2x4 TRUSS
Requires additional framing
for mounting tabs.
0
Discharge 90
to joists.
4" ROUND
DUCT
POWER CABLE
MOUNTING TABS
HOUSING
ADDITIONAL
" "
FRAMING
CEILING
JOIST
GRILLE
MATERIAL
HOUSING MOUNTED TO "I" JOIST
Requires additional framing
for mounting tabs.
Discharge 90
0
to joists.
Page 1
CEILING
*
JOIST
2 x 4
*
CEILING
JOIST or
TRUSS
" "
JOIST
*

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Broan 678

  • Página 1 MODELS 678 • 678MX • 679 • 680 • 679FL • 680FL ® Page 1 FAN/LIGHT COMBINATION VENTILATORS READ AND SAVE THESE INSTRUCTIONS WARNING TYPICAL INSTALLATIONS TO REDUCE THE RISK OF FIRE, ELECTRIC 4" ROUND SHOCK, OR INJURY TO PERSONS, OB-...
  • Página 2: Typical Installations

    MODELS 678 • 678MX • 679 • 680 • 679FL • 680FL ® Page 2 TYPICAL INSTALLATIONS INSTALL THE HOUSING (continued) (continued) New Construction 4" ROUND DUCT POWER CABLE MOUNTING HOUSING SUSPENDED CEILING MATERIAL GRILLE SUSPENDED CEILINGS Housing hung with wires - 3-point mount.
  • Página 3: Connect The Wiring

    MODELS 678 • 678MX • 679 • 680 • 679FL • 680FL ® Page 3 INSTALL THE HOUSING CONNECT THE WIRING (continued) SCHEMATIC WIRING DIAGRAM L I G H T W H T R E D B L U L I G H T...
  • Página 4: Service Parts

    This warranty supersedes all prior warranties. 97014185 Damper/Duct Connector To qualify for warranty service, you must (a) notify Broan-NuTone at the address or telephone number below, (b) give the model number and part identification and (c) describe the nature of any defect in the 98008868 Wiring Plate product or part.
  • Página 5: Ventiladores Con Lámpara

    MODELOS MODELS 678 • 678MX • 679 • 680 • 679FL • 680FL ® Página 5 Page 5 VENTILADORES CON LÁMPARA LEA Y CONSERVE ESTAS INSTRUCCIONES ADVERTENCIA INSTALACIONES TÍPICAS PARA REDUCIR EL RIESGO DE INCENDIO, DESCARGA CONDUCTO CABLE DE ALIMENTACIÓN ELÉCTRICA O LESIONES PERSONALES, OBSERVE LO...
  • Página 6: Instalación De La Cubierta

    MODELOS MODELS 678 • 678MX • 679 • 680 • 679FL • 680FL ® Page 6 Página 6 INSTALACIONES TÍPICAS INSTALACIÓN DE LA CUBIERTA (continuación) (continuación) Construcción nueva CONDUCTO REDONDO DE 4" (10.2 CM) CABLE DE ALIMENTACIÓN ALETA DE CUBIERTA...
  • Página 7: Conexión Eléctrica

    MODELOS MODELS 678 • 678MX • 679 • 680 • 679FL • 680FL ® Página 7 Page 7 INSTALACIÓN DE LA CONEXIÓN ELÉCTRICA CUBIERTA (continuación) DIAGRAMA ELÉCTRICO C O M M . R O J O A Z U L B L A N C O L A M P .
  • Página 8 Esta garantía reemplaza todas las garantías anteriores. 97014922 Cubierta Para calificar en la garantía de servicio, usted debe (a) notificar a Broan-NuTone al domicilio o al número de teléfono 97014185 Conector del regulador de tiro/conducto que se menciona abajo, (b) dar el número del modelo y la identificación de la pieza, y (c) describir la naturaleza de...

Este manual también es adecuado para:

678mx679680679fl680fl

Tabla de contenido