Troubleshooting - Truper COMP-80LV Instructivo

Ocultar thumbs Ver también para COMP-80LV:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PROBLEM
1. Compressor will not start with
initial pressure.
2. Compressor gets excessively
hot.
3. Compressor keeps on releasing
air when stopping use.
4. Compressor generates too little
air
5. Safety valve is dripping

TROUBLESHOOTING

CAUSE
Overload protector activated
Tank with pressure
Motor broken down
Damaged pressure switch
Overload protector activated
Loose cable
Switch would not release air circuit
Voltage drop in the line
Defective retention valve
Dirty air filter
Defective valves
Condensation-water drain nozzle is
open
Pressure is too high
Defective safety valve
*TASC: Truper Authorized Service Center®
SOLUTION
Restore the protector
Discharge
Go to the nearest TASC*
Go to the nearest TASC*
Turn off the compressor and wait
for it to cool, then work it again. If
the fault persists go to TASC*
Discharge
Go to the nearest TASC*
Go to the nearest TASC*
Do not use extension cables
Go to the nearest TASC*
Clean / replace filter
Go to the nearest TASC*
Close nozzle
Go to the nearest TASC*
5

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

15656

Tabla de contenido