Descargar Imprimir esta página

El-Tilslutning - Danfoss RT 1 Guia De Inicio Rapido

Ocultar thumbs Ver también para RT 1:

Publicidad

ENGLISH
Pressure switches
Only types with letter A are suitable for
1)
R717
Technical data
Range
(P
)
e
Type
Reset
[bar]
auto
RT 1
-0.8 – 5
RT 1A
min.
auto
RT 5
4 – 17
RT 5A
max.
RT 1A 017-500766 - adjustable differential
*1)
1.3 – 2.4 bar
RT 5 017-528466 - adjustable differential
*2)
0.6 – 3.0 bar
RT 5 017-539566 - adjustable differential
0.3 – 2.5 bar
Max. working pressure, PS / MWP:
22 bar / 315 psig
Max. test pressure, p': 25 bar
Maximum permissible bellows temperature:
70 °C
Enclosure: IP66 according to IEC 529
Contact load
See switch cover or fig. 4.
The marking, e.g.10 (4) A, 400 V ~ means
that max. connection current is 10 A
ohmic or 4 A inductive at 400 V ~. The max.
starting current on motor cutin (L.R.) may
be up to seven times the inductive load –
but max. 28 A.
The RT pressure controls comply with
conditions specified in VDE* 0660.
*VDE = Verband Deutscher Elektrotechniker
Fitting
A set of Pg13.5 cable gland is attached to
the RT in a separate bag. To ensure IP66
(units with automatic reset) or IP54 (units
with external reset) grade of RT enclosure
it is necessary to assemble this gland as
shown in the fig. 5. If this gland is not used
with a cable, a metal blinding should be
also assembled.
The pressure switch is designed for fitting
on the valve panel or the compressor. Use
the mounting holes pos. 25, fig. 1. If the
control is subjected to vibration, it should
be mounted on a soft intermediate base.
If pressure pulsations occur in the system,
such pulsations should be effectively damped,
e.g. by connecting the pressure switch to the
system through a capillary tube.
See fig. 7.
Mains connection
See fig. 6.
START = make. STOP = break
DIFF = differential
Cable diameter: 6 – 14 mm
© Danfoss | DCS (jmn) | 2015.11
The earth terminal 38 should be connected
to earth.
Refit protective cap.
Adjustment
See figs. 2, 3 and 6.
Set the pressure switch for minimum
Adjustable
actuating pressure (range setting).
differential
∆p
NOTE: RT 5 and RT 5A with max. reset
[bar]
should be set for maximum actuating
0.5 – 1.6
*1)
pressure (range setting). Setting is done
fixed approx. 0.5
by rotating the main spindle 44, at the
1.2 – 4
same time reading the main scale 9. The
fixed approx. 1.2
*2)
differential is set by rotating the differential
adjusting nut 19 according to the diagram
in fig. 3. Maximum actuating pressure is
the sum of the setting pressure and the
differential.
Example
A setting on "5" fig. 3. will give a differential
of approx. 1.8 bar on type RT 1A (code no.
017-500766), while the same setting on
type RT 5A will give a differential of approx.
2.3 bar.
In general, turning the main spindle
automatically moves both the maximum
and minimum actuating pressures (break
and make pressures) up or down because
of the fixed differential.
On the other hand turning the differential
adjusting nut only alters the maximum
actuating pressures.
The scale of all RT types without reset
and RT types with min. reset is calibrated
in such a way that the scale setting
corresponds to contact change-over at
minimum actuating pressure (normal
setting).
In RT switches with min. reset, the pressure
in the bellow system must increase by a
value corresponding to the differential,
before manual reset can be effected.
RT switches with max. reset have a scale
which is calibrated in such a way that
the scale setting corresponds to contact
changeover at maximum actuating
pressure. (NOTE: contrary to normal setting).
The pressure in the bellows system must
decrease by a value which corresponds to
the differential, before manual reset can be
effected.
Accessories See figs. 7 and 8.
DANSK
Pressostater
Kun typer med bogstavet A må kun
1)
anvendes til R717.
Tekniske data
Regulerings-
område
Type
Reset
(P
)
e
[bar]
auto
RT 1
-0.8 – 5
RT 1A
min.
auto
RT 5
4 – 17
RT 5A
max.
RT 1A 017-500766 - adjustable differential
*1)
1.3 – 2.4 bar
RT 5 017-528466 - adjustable differential
*2)
0.6 – 3.0 bar
RT 5 017-539566 - adjustable differential
0.3 – 2.5 bar
Tilladeligt driftstryk, PS / MWP: 22 bar / 315 psig
Maks. prøvetryk, p': 25 bar
Maks. till. temp. i bælg: 70 °C
Tæthedsgrad: IP66 iht. IEC 529
Kontaktbelastning:
Se kontaktdækslet eller fig. 4.
Mærkningen, f.eks.10(4) A, 400 V ~, angiver,
at der maks. må tilsluttes 10 A ohmsk eller
4 A induktiv belastning ved 400 V ~. Den
maksimale startstrøm ved indkobling af
motor (L.R.) må være op til syv gange den
induktive belastning – dog maks. 28 A.
RT pressostaterne opfylder betingelserne
i VDE* 0660.
*VDE = Verband Deutscher Elektrotechniker
Montering
Et sæt Pg13,5 kabelforskruning er vedlagt
produktet i en separat pose. For at sikre
kapslingsgrad IP66 (enheder med
automatisk reset) eller IP54 (enheder med
ekstern DANSK RESET) er det nødvendigt
at montere denne kabelforskruning som
vist i fig. 5. Hvis denne kabelforskruning
ikke bruges sammen med et kabel, bør der
monteres en blindprop (metal skive).
Pressostaten monteres på ventiltavlen eller
på selve kompressoren. Benyt
monteringshullerne pos. 25, fig.1. Hvis
apparatet kan blive udsat for vibrationer,
bør det monteres på et blødt underlag.
Forekommer der trykpulsationer i anlægget,
skal disse dæmpes effektivt, f.eks. ved at
tilslutte pressostaten til anlægget ved hjælp
af et kapillarrør.
See fig. 7.

El-tilslutning

See fig. 6.
START = slutte. STOP = bryde
DIFF = differens
Kabeldiameter: 6 – 14 mm
Jordforbindelse tilsluttes jordskruen 38.
Beskyttelsesdækslet monteres.
DKRCC.PI.CE0.C3.72 | 520H10128 | 2
Indstillelig
differens
∆p
[bar]
0.5 – 1.6
*1)
fast ca. 0.5
1.2 – 4
fast ca.1.2
*2)

Publicidad

loading

Este manual también es adecuado para:

Rt 1aRt 5Rt 5a