Warnings And Safety Information - Amann Girrbach ceramill aqua Instrucciones De Servicio

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

MAINTENANCE
The units are basically maintenance-free. Always re-
move any dirt with a dry cloth.
NOTE: Do not steam clean. Do not clean with water
or solvent! Adhere to the manufacturer's instructions
for use for maintenance of the laboratory turbine!
After use ensure that spray water is removed from
all parts of the milling arm with a dry, fluff-free cloth.
Then lightly oil the guide channels of the vertical
carriage if required.
WARNINGS AND SAFETY
!
INFORMATION:
The height lock ring should always be fully tighte-
ned at the swivel arm to prevent the arm suddenly
sliding down!
Protective glasses should always be worn when
milling metal, porcelain, acrylic or wax!
Anyone with long hair should tie it back pro perly
or if necessary wear a hairnet when milling!
In the case of a malfunction the unit should only
be repaired by authorised personnel!
Always use Amann accessories or AmannGirrbach
replacement parts!
Technical Data:
T/B/H:
Weight:
Accessories / Components:
Order no.:
177020
Adapter NSK Presto Aqua
177044
Adapter BienAir
177048
Adapter Sirius
177049
Adapter Acurata Turbo-Jet
177520
Worklight
Package contents:
Order no.:
177500
1 Ceramill basic unit
incl. vertical adjustment
1 Milling arm
1 Model table 90° adjustable
1 Collector tray
Instruction for use
300 x 320 x 450 mm
8,8 kg
GB
7

Publicidad

Tabla de contenido
loading

Tabla de contenido