WELDING STETTINGS
1. Welding intensity settings :
Adjust the welding current using the main knob according to the thickness and type of connection to be made. The current selected is indicated on
the display.
ARC STRIKE / IGNITION :
LIFT start : Using the torch, make contact between the electrode and the metal piece, then slightly lift the electrode to start the arc.
WELD STOP / SWITCHING TO DOWNSLOPE :
To stop the weld, slightly lift the torch, the intensity will gradually reduce (downslope).
ASSISTANCE FOR SETTING UP AND SELECTING CONSUMABLES
0.3 - 3 mm
DC
2.4 - 6 mm
4 - 8 mm
6.8 - 8.8 mm
ELECTRODE GRINDING
d
DISPLAY CURRENT/VOLTAGE DURING WELDING
During welding, the machine measures and displays the welding current and voltage. After the weld, the average current and voltage values are
displayed during 30 seconds, as soon as a knob or a button is pressed, the welding parameters are displayed.
SAVE AND RECALL WELDING SETTINGS
The current settings are automatically saved and will load next time the machine is used.
In addition to the current settings it is possible to save and recall configurations
There are 10 memory slots per mode.
The memory settings apply to :
- The main parameter (process, current setpoint)
- The secondary parameters (Hotstart, Arcforce, Upslope, etc.)
Save a configuration :
- Hold buttons
and
- Turn one of the two knobs to display
- The display flashes to indicate a memory slot (01 to 10).
- Turn the knob to select the memory slot in which the desired settings will be saved. Validate by pressing the button
Recall existing settings:
- Press and hold the buttons
- Turn the control wheel to display
- The display flashes to indicate a memory slot (01 to 10).
- Turn the control wheel to select the memory slot containing the settings to be recalled. Validate by pressing the button
QUICK LOAD « q.L. »
The Quickload is a JOB reminder mode outside welding. This mode is possible in MMA.
JOB reminders are made by briefly pressing and releasing the SWITCH of the remote control via a dedicated remote control.
E.g.: if JOB 2, 5, 7 and 10 have been created and the user has entered the number 7, then the recalled JOBs will be 2, 5 and 7.
When the mode is activated, the first JOB is recalled and displayed at the HMI (in the example: JOB 2 and display «J.02»).
If unlocked, the HMI behaves with the specificities:
- the HMI displays «J.XX» continuously as well as the parameters (welding process, Pulse, electrode type,...).
- The cycle is accessible and modifiable (the JOB is out of adjustment (*)),
IMS 220E FV CEL
Current (A)
5 - 75
60 - 150
100 - 200
170 - 220
L = 3 x d for a low current.
L = 3 x d for a high current
L
for 2 seconds.
. Confirm by pressing button
and
for 3 seconds.
. Validate by pressing the button
Electrode (mm)
Shroud (mm)
1
1.6
2
2.4
appears, release the buttons.
.
appears, release the buttons.
.
Argon flow rate (L/min)
6.5
6 - 7
8
6 - 7
9.5
7 - 8
11
8 - 9
.
.
EN