3. Troubleshooting
Problem
Bladder does not fit
into the pocket
Velcro does not
close
CO2 cartridge is
pierced immediately
when screwing in
CO2 cartridge can-
not be screwed in or
only screwed in with
much difficulty
4. Storage, care, maintenance and disposal of your RESTUBE product
Lifespan & storability
RESTUBE products are designed to have a long lifespan and can be triggered from 50 to 250(*)
times, depending on the version. Once used, the device is to be stored outside its packaging, well
ventilated and at a maximum temperature of 28°C. The maximum lifespan of the device is 5 years
from the date of purchase, assuming that the care and maintenance instructions are followed.
If used frequently (more than once per week) or in tropical climates, the product lifespan may be
shorter. If humidity is high, the device should be removed from its box. Do not put RESTUBE products
on radiators and do not dry or store them in direct sunlight.
Care
Maintain your RESTUBE product after every use. Five minutes of your time will help to make sure
that you carry on being able to enjoy the product.
>>> Take the bladder out of its bag and check all parts for external damage: Bag, bladder, trigger,
trigger cord and CO2 cartridge. None of the components should show signs of heavy use, significant
rust or damage.
>>> Following use in saltwater or chlorinated water: Remove the bladder from its bag, and rinse
both in fresh water, ensuring that the oral valve is closed and that the cartridge is screwed in first. If
the product has become particularly dirty, wash it with mild detergent or a weak solution of lye and
rinse it with fresh water afterwards. Do not use cleaning agents which contain alcohol or solvents.
20
ATTENTION
If the bladder is not positioned correctly in the pocket, correct
release is not guaranteed!
•
Position the folded bladder in the pocket so that the
nut on the trigger mechanism is facing the label with
the nut symbol
>>> The trigger cord must hang out of the pocket
•
Connect the triangular velcro 3c on the trigger cord to
velcro 3b on the flap
•
Close the flap of the pocket
Cause
Bladder is not fully
emptied
Bladder is not folded
correctly
Bladder is not positioned
correctly in the pocket
The release lever was not
switched before screwing
in the new CO2 cartridge
Dirt on the thread or
trigger mechanism
Corrective action
> Empty bladder completely
> Observe packaging instructions
> Nut on the trigger must face the
label with the nut symbol
> Close the release lever to avoid
piercing the new CO2-cartridge.
> Clean the trigger mechanism
(*)PFD by RESTUBE: Up to 50 times