Plena Power Amplifier | Manual de uso e instalación | Funcionamiento
20
19
18
Input 1
Input 2
Slave Input
Enable
Priority
100V
100V
2..24V
GND 2..24V
GND
Default Off
Default On
Input 1-Priority
Input
Input
Output
1
2
3
figure 5.3: Panel posterior LBB1938
1
3
4
6
17
15
figure 5.4: Panel posterior PLN-1P1000
Bosch Security Systems | 2006-11 | 9922 141 50751es
Input 1 Priority
Loopthrough 1
Input 2 Program
Loopthrough 2
Input 1 Priority
+
2...24V- Input 1
-
0V- Input 2
+
Input 2 Enable
-
2..24V- Enable
0V- Mute
Slave Input 100V
100V
0
0
Input 2-Progr
am
Input
4
5
6
20 19 18
20 19
7
14
9
8
17
Pilot-tone
Detector
Off On
100V
0
70V
0
8ohm
100V/70V
Selection (12A)
Priority Only
0
No Priority
0
Priority
LBB 1 938/10
8900 193 81001
Plena 480W P ower Amplifier
Max. output power 720W
Rated output power 180W
A035413
230V~,50/60Hz
N663
S/N.
NL-4827HG-10
Design & Quality
The Netherlands
16
12
10
16
14
15
Power
Fault Relays' Output
Input
Battery
Main Power
Battery
Detection
Off On
NO COM NC
NO COM NC NO COM NC
Apparatus
delivered
Direct O utput
connectored
100V
0
70V
0
8
for 230V~
Rated input
Power : 1600VA
Priority Controlled Output
24V DC In
100V
0V
100V 0V
Priority Only
No Priority
7
9
es | 22
12
11
10
8
A035413
N663
11