Descargar Imprimir esta página

Stid ARC1 Serie Procedimientos De Instalación página 2

Publicidad

Idiomas disponibles

Idiomas disponibles

ARC1 Mini Mullion reader
MA1 OEM Module
Installation instructions
Baud rate
Default Baud rate
Mode
Number of bits
Transfer mode
Stop bit
RS485
Bus architecture (RS485)
Wiring resistors R1 and R2 use extended features of the RS485 bus: FAIL-
SAFE (see RS485-AN-960).
R1 & R2: 1.5 kΩ resistor not supplied.
: 120 Ω end-of-line resistor supplied
R
T
Smart mounting plate
General tolerance following ISO NFT 58-000 standard.
STid declares that the ARC1-XY reader is compliant with the essential requirements of the Directives RED 2014/53/UE and RoHs 2011/65/UE. A copy of our
declaration is available on request from qualite@stid.com.
This device complies with Part 15 of the FCC rules and with ISED's license–exempt RSSs. Operation is subject to the following two conditions:
1) This device may not cause harmful interference.
2) This device must accept any interference received, including interference that may cause undesired operation.
Note: the manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications
could void the user's authority to operate the equipment.
This device complies with the safety requirements for RF exposure in accordance with RSS-102 issue 5 for conditions of use.
.
STid reserves the right to make change without notice, for the purpose of product improvement.
Lecteur Etroit ARC1
Module OEM MA1
Notice d'installation
RS232 / RS485 communication
9600, 19200, 38400, 57600, 115200 bauds
ARC R & S: 9600; ARC W: 38400(SSCP), 9600(OSDP)
Default broadcast address 00h
© STid - 20 PA des Pradeaux FR13850 Gréasque - NI1110A08- Page 2 sur 6 - Ed. 03/12/2020
Asynchronous
8
LSB first
1
Dimensions
ARC1/ARC1S
Declaration of compliance
Lector Estrecho ARC1
Módulo OEM MA1
Procedimiento de instalación
conforme con NOM-024 -SCFI-2013
More details about reader
communication are available
in the protocol specification
Mounting
-
Pass the cables through the hole in the base.
-
Screw the base in its final location.
-
Connect the reader.
-
Test the readings and communication.
-
Place the reader on the base (clip the top part and then
pivot it down).
-
Lock the reader with the provided screw using the
specific tool.
US
FR
ES
MA1/MA1S
(dimension in inch)

Publicidad

loading

Este manual también es adecuado para:

Ma1 serieArc1-xyArc1s-xy/ph5Arc1s-xy/bt1Ma1-xyMa1s-xy/ph5 ... Mostrar todo