MODELS WITH TRANSFORMER
The 3-position switch for the operating mode and the switch for the transformer taps are below the wall bracket in a control section behind a
water-tight rubber covering in the models DQOR 3T(B/W), DQOR 5T(B/W) and DQOR 8T(B/W)
desired settings and seal the control compartment carefully again afterwards.
A
OPERATING MODE 16 Ω / 70V / 100V
1
3-position switch to adjust the installation speaker for 70V or 100V installation amplifiers
or amplifiers with low-impedance output (16 Ohm). Move the switch to the corresponding
position prior to connecting to the amplifier.
2
TRANSFORMER TAPS
Switch for selecting the desired transformer tap (as an example model DQOR5TW).
DQOR 3T(B/W): 30W – 6W – 3W – 1.5W
DQOR 5T(B/W): 70W – 30W – 15W – 7.5W – 3W
DQOR 8T(B/W): 120W – 70W – 30W – 15W – 7.5W – 3W
OPTIONAL ACCESSORY
Rubber coverings for the speaker connection and the wall mounting plate are optionally available (2 sets included).
Item number: LDDQORWMC
A
. Lift the rubber covering in order to carry out the
1
2
9