Control Cable
Wire Color
Functions
BLACK
Power (-)
RED
LED Flash Pattern A
WHITE
LED Flash Pattern B
BLUE
Low Power
GREEN
Rear Cut-off
BROWN
Front Cut-off
The following procedures demonstrate the programming
and operating features of the flasher:
Turn on the flasher in Mode 1 (SW1). Short across the
programming pins until the desired pattern is running. Allow the
pattern to run for 15-seconds and it is now programmed.
Turn on the flasher in Mode 2 (SW1 and SW2). Short
across the programming pins till the desired pattern is running.
Allow the pattern to run for 15-seconds and the mode is now
programmed.
To operate the preselected pattern for Mode 1, close
switch SW1. To operate the preselected pattern for Mode 2, close
both switches (SW1 and SW2).
To enable low power, front cut-off, or rear cut-off, close
SW3, SW4, or SW5.
F.
Testing.
This product contains high output LED devices. To
prevent permanent eye damage, do not stare into
the light beam at close range.
After installation, check the entire system to ensure the
lights are functioning properly and siren/light system functions are
operating properly.
Pattern 1
2 @ 60 FPM 4 Pulse Alternating then 2 @ 114 FPM 2 Pulse
Simultaneous (R Pattern)
Pattern 2
60 FPM 5 Pulse Alternating
Pattern 3
60 FPM 4 Pulse Alternating
Pattern 4
63 FPM 3 Pulse Alternating
Pattern 5
75 FPM 2 Pulse Alternating
Pattern 6
122 FPM Alternating
Pattern 7
(1) 3 Pulse Alternating then (2) 2 Pulse Simultaneous Flashes
Average of 90 FPM
Table 1.
WARNING
Table 2.
III.
BASIC MAINTENANCE.
A.
Cleaning the Plastic Domes.
Crazing (cracking) of lenses will cause reduced
effectiveness of the light. Do not use cleaning
agents (which will cause crazing) such as strong
detergents, solvents, or petroleum products. If
crazing of lenses does occur, reliability of light for
emergency signaling purposes may be reduced
until lenses are replaced.
Ordinary cleaning of the plastic lenses can be accomplished
by using mild soap and a soft rag. Should fine scratches or haze
appear on a lens, they can ordinarily be removed with non-
abrasive, high quality, one-step, automotive paste cleaner/wax and
a soft cloth.
The use of other materials such as strong detergents,
solvents, petroleum products, etc. can cause crazing
(cracking) of the plastic domes.
B.
Service.
The Federal factory will service your equipment or
provide technical assistance with any problems that cannot be
handled locally.
Any units returned to Federal Signal for service,
inspection, or repair must be accompanied by Return Material
Authorization. This R.M.A. can be obtained from a local Distribu-
tor or Manufacturer's Representative.
At this time a brief explanation of the service requested,
or the nature of the malfunction, should be provided.
Address all communications and shipments to:
Federal Signal Corporation
Emergency Products Division
Service Department
2645 Federal Signal Drive.