Replacing the NanoCeram® Cartridge
NOTE: The Pre-Filter and the NanoCeram
at the same time and the LED indicator lights refer only to the
®
NanoCeram
cartridge, therefore, replace it when the flow meter's red
warning light flashes. It will also be time to replace your batteries.
1. For the NanoCeram® remove the cartridge by turning it counterclockwise
until it releases and discard used cartridge.
2. Remove the battery compartment door in the bottom of the base by
unscrewing the two screws and by gently prying the door open using a
flat screwdriver.
3. Remove the old batteries, wait 20 seconds, and then replace with two new
high quality AA batteries. This will reset the flow meter to "0" and the LED
lights will start flashing again when water is flowing through the filter.
4. Unpack the new NanoCeram® Cartridge and install, run water for 2
minutes, charge both cartridges as detailed in step 12 of the installation
instructions.
22
®
are not necessarily replaced
Troubleshooting
1.
Water is not coming out of the spout...
• Make sure the source water valves are turned on.
• Make sure the tubing is smooth and straight, without kinks.
• Remove the areator and make sure it is not blocked by any residue.
2.
Water leaks out from between the filter cartridges or at the filter inlet
assembly or filter base...
• Separate the cartridges at the point of the leak. Each of the cartridges, and
the filter inlet, should have two o-rings on the raised outlet found between
the three feet. Check to ensure that the o-rings are in place and properly
seated in the grooves provided for them.
3.
Water leaks from the tubing...
• Check the tubing for cuts or nicks. Check to ensure that the o-rings in
the 3-way-valve and in the Braided Source Water Tube are in place and
properly seated.
4.
Water continues to flow out of the Spout after water is turned off...
• Water may continue to flow from the Spout for a short time due to a build-
up of pressure within the filter but will typically stop by itself.
• Trapped air in the filter may force water out after the tap has been turned
off. To eliminate the trapped air, fill the Cartridges with water until you
see water leaking through the top hole of the Cartridges. This is known
as "charging" the cartridge and is done manually with the inlet assembly
removed from the top of the filter cartridge. See "Charging the system".
5.
Lights on the Faucet Collar do not work . . .
• Make sure that the Data Cable is properly plugged into the Data Port.
• Check batteries.
23
EN