COMFORT CLIMA
ENABLE COMFORT
RESTART DELTA
SHUTDOWN DELAY
COMFORT CLIMA
COMFORT CLIMA
2
In the inactive phases (combined with the 3rd part of the display) indicates the state of the stove.
In the active phases, it indicates the operating power of the stove.
ACTIVATE COMFORT
ENABLE COMFORT
In addition, by pressing the DOWN scroll button, you can display the power settings, that can be edited using the two scroll
DELTA RESTART
RESTART DELTA
keys
DELAY SWITCH OFF
UP/DOWN: The confirmation of any change takes place automatically within 3 seconds from the change or by pressing the con-
SHUTDOWN DELAY
firmation key. A sound signal indicates that the change has been confirmed.
COMFORT CLIMA
ENABLE COMFORT
The first setting allows the activation of the COMFORT CLIMA function. This function is intended to ensure that the room tem
RESTART DELTA
perature set is maintained steady upon setting the maximum period of "X" minutes (SWITCH-OFF DELA Y: 5 MIN) before switch-ing
to ECO STOP phase. The STOVE maintains this state until the temperature drops below the set value (DELTA COMFORT CLIMA:
SHUTDOWN DELAY
5°C). For example, with the room temperature at 21 ° C, the stove switches of f when this temperature is reached and restarts when
the temperature reaches 16°C (21°C - 5°C). You can also activate the function using an external thermostat, keeping in mind that this
3
does not include the value of hysteresis.
Press the key for several times until the Stand-by page is displayed.
Time and date setting
Setting
Below are given the steps for accessing the relative menu.
Below are the steps to follow, starting from the Home screen, to access the Home menu.
MENU
MANUFACTURER
TECHNICIAN
ENGINEER
PRODUCER
Press the key "access menu" to
access
the
MENU page
After following the above procedure
SETTINGS
Settings > Enable thermostat
DATE-TIME
ENABLE EXT. TH.
CONTRAST
Settings > Enable thermostat
FW VERSION
ADJUST
LANGUAGE
ENABLE EXT. T
Press the key
"confirm" to
access the
SETTINGS
page
Press the "enter" key
to access the
SETTINGS
ENABLE THERMOSTAT
Press the key
"confirm"
to enable the function.
Settings > Season
In "Home" mode, instead of room temperature measured and settable, appears the line T ON if the room in which the
ENABLE EXT. T
thermostat is installed has not reached the temperature requested or the writing T OFF if the temperature in the room is
reached.
Press the key
"confirm" to
access the
SETUP
SETTINGS
Use the UP/DOWN keys to change the WINTER/
SUMMER season. Function that can be set when
working with DHW puffer (Boiler).
See chap. Evolved hydraulic diagrams
Use and maintenance manual Rc-Rv 120 Touch steel
MENU
USER
USER
Press the key
"confirm"
to access the
USER page
Manuale utente PALMARE IDRO TOUCH RADIO
SETTING
DATE-TIME
DATE - HOUR
SEASON
Press the key "con-
ENABLE T.EXT
firm"
CONTRAST
CONTRAST
to access the page
VERSION FW
FW VERSION
LANGUAGE
ADJUST
DATE-TIME
ADJUST
LANGUAGE
Press the key
"selection" to switch to
ENABLE THERMOSTAT.
Press the key for several
to return to
"STAND BY" page
DATE-TIME
SEASON
CONTRAST
FW VERSION
LANGUAGE
ADJUST
Press the key
"selection" to switch
to the function
CONTRAST.
ENABLE COMFORT
COMFORT CLIMA DELTA
DELAY SWITCH OFF
SHUTDOWN DELAY
USER
USER
SCREW FEEDING
LOADING AUGER
CHRONOTHERMOSTAT
CHRONOTHERMOSTAT
AIR-PELLET SET
STOVE STATE
SET AIR-PELLET
STOVE STATUS
SETTING
DATE - HOUR
DATE-TIME
ENABLE EXT. T
ENABLE T.EXT
SEASON
CONTRAST
CONTRAST
VERSION FW
FW VERSION
ADJUST
LANGUAGE
LANGUAGE
ADJUST
Press the increase key to change every single value
In Stand-By mode, instead of room temperature measured
and settable, appears the line T ON if the room in which
Press the increase key to change every single value
the thermostat is installed has not reached the temperature
requested or the writing T OFF if the temperature in the
room is reached.
Press "confirm" to confirm the settings and switch to the next
value.
times
By pressing the key "back" for several times you will display
the stand-by page.
DATE-TIME
ENABLE EXT. T
SEASON
CONTRAST
FW VERSION
LANGUAGE
ADJUST
By pressing the following key you will confirm of data
and switch to the page within SETTINGS menu.
ENABLE COMFORT
Rev.1 11/03/2021
COMFORT CLIMA DELTA
DELAY SWITCH OFF
SHUTDOWN DELAY
USER
USER
COMFORT CLIMA
COMFORT CLIMA
SETTING
SETTINGS
Press the key "selection" for
"selection"
to switch to the second page
of USER MENU and select
SETTINGS.
Vers. 01 del 07/04/15
ENABLE THERMOSTAT
Press the key
"confirm"
to access the function
Press the key
"confirm"
to access the function
Pag.39
Pag.31
WINTER
SUMMER