Select Custom Settings
To display current settings, tap the Timeout (
or PIR Sensitivity (
) button. The indicator LED (
P
illuminate.
• Timeout and Sensor Mode settings may have different settings for each circuit. In this case, the
LED for Circuit 1 settings will illuminate, followed by the LED for Circuit 2 settings.
Change Settings
1
Press and hold the desired programming button (
(about 3 seconds). This will change settings for BOTH circuits.
• Timeout (
) and Sensor Mode (
) may be adjusted independently for EACH circuit. Holding
M
or
AND
or
simultaneously will program settings for that specific circuit.
M
T
T
1
2
2
Tap the same programming button to cycle to your desired setting.
3
Press and hold the same programming button until the
(about 3 seconds).
Default settings
are shown in bold
IL
Indicator LEDs
Timeout Button
1
30 minutes
15 minutes
5 minutes
1 minute
Sensor Mode Button
1
Occupancy
2
(Auto-ON / Auto-OFF)
Occupancy with Learning ALD
3
Occupancy with Fixed ALD
4
Vacancy
2
(Manual-ON / Auto-OFF)
M
Sensor LED (behind lens)
Pulses green for ultrasonic and amber
for PIR detection during Test mode.
1
Using ONLY the
or
to enter programming mode will set BOTH circuits to the new setting.
M
Holding
or
and
or
simultaneously will program settings for that specific circuit.
M
T
T
1
2
2
Circuit 1 Default: Occupancy; Circuit 2 Default: Vacancy.
3
ALD (Ambient Light Detection) Learn mode will turn lights on only if natural light in room is low. If
switch turns on when there is enough natural light, or if switch does not turn on when there is not
enough natural light, press the tap button within 5 seconds of entering the room. Over time, the
switch will learn your preferred setting. If both circuits are set to Occ with Learning ALD mode, they
will learn the SAME threshold.
4
ALD (Ambient Light Detection) Fixed mode will turn the lights on only if natural light in room is low. The
light level at which lights will automatically turn on (or stay off) can be adjusted through the "Set ALD
Fixed Level" setting in "Additional Settings" section.
Technical Assistance: www.lutron.com
®
), Sensor Mode (
), Ultrasonic Sensitivity (
M
) that corresponds to the current setting will
IL
,
,
, or
) until an
begins to flash
M
P
IL
goes solid to lock your selection
IL
Circuit 1
Tap button
(tap on/off)
Circuit 2
Tap button
(tap on/off)
Ultrasonic Sensitivity
Button
High
30
m
Hi
Medium
15
Med
Low
5
Low
Off
1
Off
Mode
PIR
PIR Sensitivity
Button
Occ
Hi
Lrn
Med
High
Fixd
Low
Medium
Vac
Min
Low
Minimum
Ultrasonic Transducers
PIR Lens
|
U.S.A., Canada, Caribbean: 1.800.523.9466
Additional Settings
Note: Additional product information, including "Circuit Swapping", and other programming
),
options and wiring diagrams are available at www.lutron.com/DTMaestroInstall
Test Mode
Test Mode is a short timeout (less than 15 seconds) that will test the coverage of the sensor at the
current settings.
To enable Test Mode:
1. Wait 2 minutes after initial power up.
2. Press and hold either
3. The device will exit Test Mode automatically after 5 minutes of inactivity, or when any button is
pressed.
Note: An amber LED flashes to indicate PIR detection, a green LED flashes to indicate ultrasonic
detection. You may hold
sensitivity of that specific technology.
Restore Default Settings
Press and hold
sensor's settings back to their defaults.
T
Off-While-Occupied
1
When Off-While-Occupied is Enabled: After manual shutoff, the sensor will keep lights off as long
as the space is occupied and the timeout has not expired. This setting is best for rooms where
presentations are given and lights may be kept off during occupancy. This is the default setting.
T
When Off-While-Occupied is Disabled: After manual shutoff, the sensor will keep lights off for
2
25 seconds before looking for motion. If motion is detected, the lights will turn back on. This
setting is best for high‑traffic areas like bathrooms and hallways.
Change Setting:
1. Press and hold
2. Tap
to cycle to your desired setting.
P
3. Press and hold
P
IL
Off-While-Occupied Disabled
Off-While-Occupied Enabled
P
Setting Fixed ALD Level
1. a. For Circuit 1: Press and hold
b. For Circuit 2: Press and hold
2. The Ambient Light Detect light level will now be displayed on the
your desired setting.
3. Press and hold
M
Light Level
IL
High: turns lights ON unless room is very bright
Medium
Low
(Default when in ALD Fixed mode)
Minimum: turns lights ON only when room is dark
|
Mexico: +1.888.235.2910
|
Others: +1.610.282.3800
or
until the PIR lens flashes (about 7 seconds).
T
T
1
2
or
for 2 seconds while in test mode to test the current
P
and
until all
blink slowly (about 7 seconds). This will restore ALL of the
P
IL
and
P
at the same time until an
IL
begins to flash (about 3 seconds).
until the
IL
goes solid to lock your selection.
(Default)
and
until the
begins to flash (about 3 seconds).
M
IL
M
and
P
until the
IL
begins to flash (about 3 seconds).
until the
IL
goes solid to lock your selection.
IL
. Tap
to cycle to
M