Opening The Lid; Removing Gland Plates; Closing The Enclosure; Tightening Values - Weidmuller Klippon TB MH Instrucciones De Montaje

Ocultar thumbs Ver también para Klippon TB MH:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 67

Opening the lid

Open the quarter lock with a suitable tool (refer to diagram 1 below). After opening the
quarter lock, the lid can be opened up to approximately 130°. It's not possible to remove
the Lid without a tool.
1
2

Removing gland plates

If gland plates are to be used remove them by loosening the gland plate screws with a
suitable tool. Afterwards the plates can be detached.

Closing the enclosure

Ensure that all lid, gland plate, earth stud screws are fully tightened in a crosswise
manor after installation.

Tightening Values

Lid, Gland plates & mounting screws for mounting plates (when present): 2.5 Nm
M10 earth stud (out-/inside):
15.0 Nm
M6 earth stud inside:
6.0 Nm
11

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Klippon tb qlKlippon tb fs

Tabla de contenido