NuTone QTXEN Serie Guia De Instalacion
Ocultar thumbs Ver también para QTXEN Serie:

Publicidad

Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

QTXEN SERIES
ULTRA SILENT
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equip-
ment to prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authori-
ties.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to
a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit (ceiling installation only).
8. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a
12/12 pitch (45 degree angle). Duct connector must point up.
DO NOT MOUNT THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4. Please read specification label on product for further informa-
tion and requirements.
Installer: Leave this manual with the homeowner.
MODELS QTXEN050 • QTXEN080 • QTXEN110
To register this product visit:
www.nutone.com
FANS
TM
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appear-
ance - lower or remove grille and vacuum interior of unit with the
dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the
motor bearings are making excessive or unusual noises, replace
the blower assembly (includes motor and impeller).
OPERATION
Use an on/off switch or a solid-state speed control to operate
this fan. See "Connect Wiring" for details. Use of speed controls
other than the NuTone Models 78V and 78W may cause a motor
humming noise.
WARRANTY
NUTONE THREE YEAR LIMITED WARRANTY
NuTone warrants to the original consumer purchaser of its products that
such products will be free from defects in materials or workmanship for
a period of three years from the date of original purchase. THERE ARE
NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT
NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE.
During this three-year period, NuTone will, at its option, repair or replace,
without charge, any product or part which is found to be defective under
normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP
STARTERS AND TUBES. This warranty does not cover (a) normal main-
tenance and service or (b) any products or parts which have been subject
to misuse, negligence, accident, improper maintenance or repair (other
than by NuTone), faulty installation or installation contrary to recommended
installation instructions.
The duration of an implied warranty is limited to the three-year period as
specified for the express warranty. Some states do not allow limitation
on how long an implied warranty lasts, so the above limitation may not
apply to you.
NUTONE'S OBLIGATION TO REPAIR OR REPLACE, AT NUTONE'S OP-
TION, SHALL BE THE PURCHASER'S SOLE AND EXCLUSIVE REMEDY
UNDER THIS WARRANTY. NUTONE SHALL NOT BE LIABLE FOR INCI-
DENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF
OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some
states do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may also have other
rights, which vary from state to state. This warranty supersedes all prior
warranties.
To qualify for warranty service, you must (a) notify NuTone at the address
or telephone number stated below, (b) give the model number and part
identification and (c) describe the nature of any defect in the product or
part. At the time of requesting warranty service, you must present evidence
of the original purchase date.
Broan-NuTone LLC
Hartford, Wisconsin
www.nutone.com
888-336-3948
Page 1

Publicidad

Tabla de contenido
loading

Resumen de contenidos para NuTone QTXEN Serie

  • Página 1 This warranty supersedes all prior warranties. impellers, keep drywall spray, construction dust, etc. off power To qualify for warranty service, you must (a) notify NuTone at the address unit. or telephone number stated below, (b) give the model number and part 4.
  • Página 2: Typical Installations

    MODELS QTXEN050 • QTXEN080 • QTXEN110 TYPICAL INSTALLATIONS Page 2 Housing mounted Housing mounted anywhere be- to I-joists. tween trusses us- ing hanger bars. Housing mounted PLAN THE INSTALLATION anywhere be- tween I-joists COOKING AREA using Do not install above or inside this area.
  • Página 3 MODELS QTXEN050 • QTXEN080 • QTXEN110 Page 3 INSTALL HOUSING & DUCT 1a. Mount SCREW (2) HOLE FOR OPTIONAL housing to SCREW MOUNTING (4) joist or I-joist. Use a pliers to bend housing TABS out to 90 . Hold housing in place so that TABS the housing tabs...
  • Página 4: Service Parts

    Key No. Part No. Description Replacement parts can be ordered on our web- 97016466 Housing site. Please visit us at 97016450 Duct Connector-6” www.nutone.com 98010102 Wiring Plate 99170245 Screw, #8-18 X .375 97018010 Wire Panel/Harness Assembly 97017782 Blower Assembly (QTXEN050) 97020047...
  • Página 5: Ventiladores Ultra Silenciosos Serie Qtxen

    12/12 (ángulo de 45 grados). NO MONTE ESTE Para tener derecho al servicio de la garantía, usted debe (a) notificar a NuTone PRODUCTO EN UNA TECHO. a la dirección y número de teléfono que aparecen abajo, (b) proporcionar el 3.
  • Página 6: Instalaciones Típicas

    MODELOS QTXEN050 • QTXEN080 • QTXEN110 Página 6 INSTALACIONES TÍPICAS Montaje de la cubierta en Montaje de la cualquier parte cubierta en vigu- entre armaduras etas “I” . por medio de barras de sus- pensión. PLANIFICACIÓN DE LA Montaje de la cubierta en cu- INSTALACIÓN alquier parte en-...
  • Página 7: Instale La Cubierta Y El Conducto

    MODELOS QTXEN050 • QTXEN080 • QTXEN110 Página 7 INSTALE LA CUBIERTA Y EL CONDUCTO 1a. Instale la ORIFICIO PARA MONTAJE CON TORNILLO (2) cubierta en TORNILLO OPCIONAL (4) las viguetas o viguetas “I” . Con un alicate, doble las LENGÜETAS de la cubierta a 90°.
  • Página 8: Conexión Eléctrica

    Pieza n. Descripción se pueden ahora pedir en 97016466 Cubierta nuestro Web site. Visítenos 97016450 Conector del conducto (6 pulg.) por favor en www.nutone.com 98010102 Placa de cableado 99170245 Tornillo n. 8-18 x 0.375 97018010 Conjunto del panel de cableado/arnés...