ALIGNMENT AND ADJUSTMENTS
To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before
servicing, unless testing requires power.
ERROR ITEMS AND DIAGNOSTIC CODES
An occurrence of an Error will make a sound of error melody for 5 sec and continuously show one
of the Error Displays from the following errors.
Error Display
tE
hE
HE
do
dE
dF
bE
bE2
FE
Et
Technical_information-02365J-01_EN.indd 2
WARNING
Trigger
The Termistor resistance is very low
or high.
Invalid heating Temp in running the
dryer
Running the dryer with door open
Invalid door state for more than
256 milliseconds
Invalid state of key circuit short for
30 secs(all models)
Invalid power source Frequency
Invalid state of Eeprom
communication
Action Taken
Check for:
- Clogged lint screen.
- Restricted vent system.
- Check Thermistor resistance.
Check for:
- Restricted vent system.
- Check Thermistor resistance.
Check for:
- Close the door, and run the dryer
- Loose or open wire terminals in
Door Sense circuit.
Check for:
- Loose or open wire terminals in
Door Sense circuit.
Check for:
- Display PCB key circuit short or not
Check for:
- Not using regular power source
frequency
- Invalid power frequency sense
circuit
Check for :
- PCB with Eeprom circuit.
2
2012-09-11
3:09:09