SETTING PROGRAMS
TIP: When verifying your programs ensure that the settings do not overlap, especially when using the block
option. If there are program settings overlapping, the timer ON or OFF will be executed according to program
time, not by program number. Program OFF has the priority over program ON.
1. Press TIMER button and release. LCD shows ON_1. The first ON setting can be made now.
2. Press WEEK button to set the day or block of days. Set the time by pressing HOUR and MIN button.
3. Press TIMER button again to finish the first ON setting and enter into the first OFF setting. LCD shows
OFF_1. By repeating 2 to make the first OFF setting.
4. Press TIMER button again to finish the first OFF setting and enter into the 2
to program remaining settings. Press TIMER button and hold for 2 seconds to enter fast advance.
5. After completing settings, press CLOCK button. The timer is ready to operate.
EXAMPLE: Timer ON at 17:15 and OFF at 22:30 everyday
a. Press TIMER once and release. LCD displays ON_1
b. Press WEEK till LCD displays "MO,TU,WE,TH,FR,SA,SU"
c. Press HOUR till LCD displays 5:00PM or 17:00
d. Press MIN till LCD displays 5:15PM or 17:15
e. Press TIMER again and release. LCD displays OFF_1
f. Repeat the above b,c and d till LCD displays "MO,TU,WE,TH,FR,SA,SU",10:30PM or 22:30
MANUAL ON/AUTO/MANUAL OFF SETTING
Operating modes can't be changed during program settings.
1. Press ON/AUTO/OFF button to revert the three modes in turn.
2. The programs can only be executed in AUTO mode. When AUTO is selected, the timer operates as the
programs. In MANUAL ON or MANUAL OFF mode all programs are ignored and the timer doesn't operate.
When MANUAL ON mode is selected, power output is always ON. When MANUAL OFF mode is selected,
power output is permanently off.
3. When the mode is turned from MANUAL ON to AUTO, the timer will keep the setting of MANUAL ON until
to the next timer setting.
RANDOM FUNCTION
1. Press RANDOM button. LCD displays R(RANDOM). RANDOM function is activated.
2. When RANDOM is activated,the timer will be in On position randomly for 10-31 minutes during the time
gap----from 6:00PM to 6:00AM.
3. Press the RANDOM button again to cancel this function. Random function can't be set during program
settings.
4. The RANDOM function can only be executed in AUTO mode between 6:00PM and 6:00AM.
12/24 HOUR MODE
Press CLOCK and TIMER simultaneously to turn the time display between 12 and 24 hour mode.
SUMMERTIME FUNCTION
1. Press CLOCK and ON/AUTO/OFF simultaneously. LCD shows S (Summer time). Clock advances 1 hour.
2. To revert to winter setting, press the two buttons again. Clock moves backward 1 hour. S disappears in
LCD.
SPECIFICATIONS
Voltage
Max Load
Min Setting Time
DISPOSAL OF THE UNIT
This marking indicates that this product should not be disposed with other household wastes
throughout the EU. To prevent possible harm to the environment or human health from
uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material
resources.
To return your used device, please use the return and collection systems or contact the retailer
where the product was purchased. They can take this product for environmental safe recycling.
230VAC, 50Hz
16(2) A, 3600W
1 Minute
Operating temperature
Accuracy
Battery backup
nd
ON setting. Repeat 2 and 3
o
o
-10
C to +40
C
+/- 1 minute per month
NiMH 1.2V >100hours