Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 19
1. Safety Information
To all residents of the European Union
Important environmental information about this product
This symbol on the device or the package indicates that disposal of the device after its lifecycle could harm
the environment. Do not dispose of the unit (or batteries) as unsorted municipal waste; it should be taken to
a specialized company for recycling. This device should be returned to your distributor or to a local recycling
service. Respect the local environmental rules.
If in doubt, contact your local waste disposal authorities.
Thank you for choosing Perel! Please read the manual thoroughly before bringing this device into service. If the device
was damaged in transit, don't install or use it and contact your dealer.
The meter is completely portable, LCD, 3 1/2 digit clamp with insulation test function (with option 500V insulation
tester unit). It has been designed according to IEC-1010 concerning electronic measuring instruments with an
overvoltage category (CAT II) and pollution 2 and safety requirements for handheld current clamps for electrical
measurement and test.
Follow all safety and operating instructions to ensure that the meter is used safely and is kept in good condition.
1.1 Preliminary
When using this meter, the user must observe all normal safety rules concerning :
- Protection against the dangers of electronic current.
- Protection of the meter against misuse.
Full compliance with safety standards can be guaranteed only if used with test leads supplied. If necessary,
they must be replaced with the same model or same electronic ratings. Measuring leads must be in good
condition.

1.2 During Use

Never exceed the protection limit values indicated in specifications for each range of measurement.
When the meter is linked to measurement circuit, do not touch unused terminals.
When the value scale to be measured is unknown beforehand, set the range selector at the highest position.
Before rotating the range selector to change function, disconnect test leads from the circuit under test.
When carrying out measurements on TV or switching power circuits, always remember that there may be high
amplitude voltage pulses at test points which can damage the meter.
Never perform resistance measurements on live circuits.
Always be careful when working with voltage above 60Vdc or 30Vac rms.
When the jaw are open and will be connected to the conductor under test, your fingers must keep behind the
barrier indicator.
Never ground yourself when taking electrical measurements. Do not touch exposed metal pipes, outlets,
fixtures, etc. which might be at ground potential. Keep your body isolated from ground by using dry clothing,
rubber shoes, or any approved insulating material.
ECM2
ECM2 – DIGITAL CLAMP MULTIMETER
3
PEREL

Publicidad

Tabla de contenido
loading

Tabla de contenido