Speed 3 - 10 minutes (the number "3" and a small flashing LED light
appear on the display)
High-speed - 5 minutes (the number "4" and a small flashing LED light
appear on the display)
Press button 1 or button 4 to turn the hood off while the speed timer is in
function; by pressing button 2, the hood returns to the set speed.
Grease filter indicator
After 80 hours of operation, the number "1" starts flashing on the display.
Press and hold button 1 or 3 to reset the indicator.
Carry out maintenance on the grease filter according to the indications of this
manual.
Charcoal filter indicator
After 320 hours of operation, the number "2" starts flashing on the display.
Press and hold button 1 or 3 to reset the indicator.
Carry out maintenance on the charcoal filter according to the indications of
this manual.
When both filter signals appear simultaneously, numbers "1" and "2" will
alternately flash on the display.
Reset the indicator by performing the above-mentioned procedure twice.
The first operation resets the grease filter indicator, while the second
operation resets the charcoal filter indicator.
The charcoal filter indicator is not active in the standard mode.
If the hood is used in the recirculation mode, the charcoal filter indicator must
be activated.
Perform the following steps to activate the charcoal filter indicator:
Turn the hood off and keep buttons 2 and 3 pressed for 3".
The numbers "1" and "2" will flash for 2" once the function has been
activated.
Charcoal filter indicator deactivation:
Turn the hood off and keep buttons 1 and 2 pressed for 3".
The number "1" will flash for 2" to indicate that the function has been
deactivated.
Maintenance
ATTENTION! Before performing any maintenance operation, isolate the
hood from the electrical supply by switching off at the connector and
removing the connector fuse.
Or if the appliance has been connected through a plug and socket, then the
plug must be removed from the socket.
The cooker hood should be cleaned regularly (at least with the same
frequency with which you carry out maintenance of the fat filters) internally
and externally.
Clean using the cloth dampened with neutral liquid
detergent. Do not use abrasive products. DO NOT USE ALCOHOL!
WARNING: Failure to carry out the basic cleaning recommendations of the
cooker hood and replacement of the filters may cause fire risks.
Therefore, we recommend oserving these instructions.
The manufacturer declines all responsibility for any damage to the motor or
any fire damage linked to inappropriate maintenance or failure to observe
the above safety recommendations.
Grease filter
Fig. 7-23
This must be cleaned once a month (or when the filter saturation indication
system – if envisaged on the model in possession – indicates this necessity)
using non aggressive detergents, either by hand or in the dishwasher, which
must be set to a low temperature and a short cycle.
When washed in a dishwasher, the grease filter may discolour slightly, but
this does not affect its filtering capacity.
Charcoal filter (filter version only)
Fig. 22
Type 20 LONG LIFE - Washable activated charcoal filter
The charcoal filter can be washed once every two months (or when the filter
saturation indication system – if envisaged on the model in possession –
indicates this necessity) using hot water and a suitable detergent, or in a
dishwasher at 65°C (if the dishwasher is used, select the full cycle function
and leave dishes out).
Eliminate excess water without damaging the filter, then remove the
mattress located inside the plastic frame and put it in the oven for 10 minutes
at 100° C to dry completely. Replace the mattress every 3 years and when
the cloth is damaged.
Type 15 - NON-washable activated charcoal filter
The saturation of the charcoal filter occurs after more or less prolonged use,
depending on the type of cooking and the regularity of cleaning of the grease
filter.
In any case it is necessary to replace the cartridge at least every four
mounths (or when the filter saturation indication system – if envisaged on the
model in possession – indicates this necessity).The charcoal filter may NOT
be washed or regenerated.
Replacing lamps
Fig. 24
Disconnect the hood from the electricity.
Warning! Prior to touching the light bulbs ensure they are cooled down.
Replace with a new 12 Volt, 20 Watt (Maximum) halogen light made for a G-
4 base SUITABLE FOR USE IN OPEN LUMINAIRES. Follow package
directions and do not touch new light with bare hands.
11