Instruction Manual
7.
ELECTRODE INSTALLATION
NOTE: numbers shown below are referring to Fig. 1-2 chapter 6
COMMANDS DESCRIPTION to Page 4-5.
7.1
ELECTRODE HOLDER CONNECTION
1. Connect the positive power cable (+)
of the ELECTRODE HOLDER to socket
(16).
2. In case reverse polarity electrodes are
used, connect the ELECTRODE
HOLDER to socket (17).
Negative polarity (-).
7.2
CONNECTION TO BASE MATERIAL
1. Connect the ground cable to socket
(17). Negative polarity (-).
2. Secure the other end of the ground
cable to the base material, making sure
that a good electrical contact is esta-
blished.
3. In case reverse polarity electrodes are
used, connect the ground cable to socket
(16). Positive polarity (+).
6
GB
HOT START: improves the start, during the arc starting procedure,
the current increases in percentage its value for 0,3 sec.
ARC FORCE: improves the stability of the arc during welding, the
current increases automatically during the transfer of the material.
ANTISTICKING: after 2 sec. of short circuit between the electrode
and the base material, the generator turns OFF. See page 17.
Hot Start
Welding Current
0,3 sec
Start
INOXA SERIES
In ELECTRODE mode, consider
that functions:
HOT START
ARC FORCE
ANTI STICKING
are all automatic and pre-set for the
electrode that needs to be welded.
ATTENTION! If the generator
is connected to the COOLER
UNIT, it is necessary to con-
nect the By-pass tube (23A)
to the quick release connec-
tors (23).
It is also possible to connect
a TIG water cooled torch.
See page 8