2.3. Non-approved cleaning agents
∙ Halogenated cleaning agents.
∙ Flammable and highly flammable cleaning agents with flash point < 60°C, except for cleaning agents with flash point >
40°C when technical ventilation (exhaust system) is installed.
2.4. Standards
EN
∙ Indispensably note the guideline for devices for cleaning workpieces with cleaning agents (amongst others the
DGUV-information 209-088, formerly BGR 180)! The same applies to the requirements of the Water Management Act
(German WHG), the ordinance on systems for handling water-polluting substances (German AwSV) as well as leaflet
M043 – Hydrocarbon based cleaner (formerly BGI 880).
3. OPERATING PRINCIPLE
3.1. How the machine works
∙
The IBS-Pump pumps the cleaning liquid through a hose to the IBS-Cleaning Brush. The workpiece is placed on the support rack
and is cleaned with the brush and cleaning liquid.
∙
The dirty cleaning agent flows back into the drum. The dirt particles sink to the bottom of the drum. When the cleaning effect of the
cleaning agent declines, the drum must be replaced with a new drum of IBS-Special Cleaning Agent.
∙
Old goods will be collected by IBS Scherer and recycled as long as the mixing ban has been adhered to.
3.2. Safety information
∙
See section 6
4. TRANSPORT
4.1. Handling
∙
Take great care when transporting the device to the installation site at the customer's premises in order to prevent damage.
∙
Secure the device on the pallet to ensure that it does not slip off.
∙
When transporting the drum, read and follow the data sheet for the cleaning agents.
4.2. Transport aids
4.2.1. Transport using a crane
∙
Attach the crane cables to the pallet and lift the device carefully. Pay special attention to the centre of gravity. The device may tip.
NOTE: The crane must have a carrying capacity of at least 200 kg.
4.2.2. Transport using a fork-lift
∙
Insert the fork-lift between the longitudinal pieces on the wooden pallet.
∙
Lift the unit and transport it.
46
IBS-BA_Typ_BK 50-DE_CZ_PL_ES_EN_04.2020