Figure 4.
Wedge
Lock
1/4-20 Lock Screws
Torque to 20 in-lbs.
Figure 5.
Slipfitter Mounting
Tools Required
#2 Phillips head screwdriver, socket wrench, ¾" socket
(Axcent Large only), 3/8" square nut driver, torque wrench.
1.
The fixture comes with a wall mount wedge plate pre-
installed. Remove the wall mount wedge plate and
discard. (Figure 1.)
2.
Make wiring connections between fixture and slipfitter
using supplied outdoor-rated wire nuts. Refer to wiring
diagram for power connections. (Figure 3.)
3.
Attach the slipfitter assembly to the fixture. Ensure that
the luminaire supply leads are completely underneath
the wedge plate and are not pinched. Tighten the two
¼-20 screws on the fixture to 20 in-lbs. (Figure 6.)
Wire Hanger Slot On Wedge Plate
Wire Hanger
Wall
Wall
Installation Instructions – Axcent (Small & Large)
Wedge Plate
Axcent Fixture
Wedge Plate
(3X)Lock Nuts
Torque to 15 ft-lbs.
(3X)Set Screw
Torque to
10 in-lbs.
Pole
(2 3/8" To
2 7/8" O.D)
Figure 6. Axcent Large
4.
Loosen (3) set screws so that the slipfitter will slide
easily onto the pole. Make wiring connections between
the slipfitter and the pole. Refer to wiring diagram for
power connections. (Figure 3.)
5.
Place the wires down into the pole or up into the
slipfitter body. Lower the slipfitter onto the top of the
pole. Ensure that the supply leads are not pinched.
(Figure 6.)
6.
Tighten the (3) set screws and lock nuts. (Figure 6-7 .)
7 .
Remove (2) cover plate screws and cover plate.
(Figure 6.)
8.
To change luminaire tilt angle, loosen center bolt, rotate
fixture to the desired angle, and tighten center bolt.
(Figure 6-7 .)
9.
Install cover plate, tightening the (2) cover plate screws.
(Figure 6-7 .)
COOPER LIGHTING SOLUTIONS
1/4-20 Lock Screws
Torque to 20 in-lbs.
IB514031EN
Installation instructions
1/2" Bolt
Torque to
30 ft-lbs.
Cover
#8-32 Screws
Torque to
15 in-lbs.
3