Maximum Air pressure
Minimum air pressure
Maximum delivery
Air inlet thread
Oil outlet thread
Air piston diameter
Air piston stroke
G
These pumps can be mounted directly on drums, tanks, or on a
wall bracket fitted with a 2" bung (Fig 2).
•
Loose the star nut (836150) of the bung adaptor to remove
the inferior nut (736152), and screw this into the 2" bung
opening of the drum or bracket.
•
Place the star nut (836150) and the ring (834150) on the
suction tube.
•
Introduce the pump through the opening and fasten the
assemble at the desired height by tightening the star nut.
2
834 811 R.06/14
Samson Corporation • One Samson Way • N.C. 28778 Swannanoa • Phone: 00 1 8286868511 • Fax: 00 1 8286868533
Technical data/ Datos técnicos
Presión de aire máxima
Presión de aire mínima
Caudal máximo
Rosca entrada aire
Rosca salida aceite
Diámetro pistón de aire
Recorrido del pistón de aire
Installation / Instalación
E
Las bombas pueden ser montadas directamente sobre bidones,
cisternas o sobre un soporte mural que dispongan de rosca 2"BSP
H (Fig. 2).
•
Afloje la tuerca en estrella (836150) del adaptador para
extraer la parte inferior del mismo (736152) y roscarla en el
brocal de 2" del bidón o del soporte.
•
Coloque la tuerca en estrella (836150) y el anillo (834150) del
adaptador en el tubo
•
Introduzca la bomba por el brocal y apriete el conjunto a la
altura deseada.
836152
834150
736152
10 bar (140 psi)
3 bar (40 psi)
25 l/min
3/8" (H) / (F)
3/4" (H) / (F)
88 mm (~4")
75 mm (3")
Fig. 2