Maximum Air pressure
Minimum air pressure
Maximum delivery
Air inlet thread
Oil outlet thread
Air piston diameter
Air piston stroke
G
These pumps can be mounted directly on drums, tanks, or on a
wall bracket fitted with a 2" bung (Fig 2).
Loose the star nut (836150) of the bung adaptor to remove
the inferior nut (736152), and screw this into the 2" bung
opening of the drum or bracket.
Place the star nut (836150) and the ring (834150) on the
suction tube.
Introduce the pump through the opening and fasten the
assemble at the desired height by tightening the star nut.
2
834 811 R.06/14
Samson Corporation • One Samson Way • N.C. 28778 Swannanoa • Phone: 00 1 8286868511 • Fax: 00 1 8286868533
Technical data/ Datos técnicos
Presión de aire máxima
Presión de aire mínima
Caudal máximo
Rosca entrada aire
Rosca salida aceite
Diámetro pistón de aire
Recorrido del pistón de aire
Installation / Instalación
E
Las bombas pueden ser montadas directamente sobre bidones,
cisternas o sobre un soporte mural que dispongan de rosca 2"BSP
H (Fig. 2).
Afloje la tuerca en estrella (836150) del adaptador para
extraer la parte inferior del mismo (736152) y roscarla en el
brocal de 2" del bidón o del soporte.
Coloque la tuerca en estrella (836150) y el anillo (834150) del
adaptador en el tubo
Introduzca la bomba por el brocal y apriete el conjunto a la
altura deseada.
836152
834150
736152
10 bar (140 psi)
3 bar (40 psi)
25 l/min
3/8" (H) / (F)
3/4" (H) / (F)
88 mm (~4")
75 mm (3")
Fig. 2