AHT Cooling Systems GmbH | en-US
CAUTION
Heavy appliance parts.
Hands may become trapped.
§ Take care with fingers and hands.
§ Wear protective gloves.
NOTICE
Material and property damage due to missing
parts in the appliance.
§ Check the packaging for loose parts.
§ Do not dispose of loose parts; clarify their use with
the maintenance service [see } Chapter 11.3.2].
8
Setup and installation
Responsibility
– Operating company
Technical data [see } Chapter 3.2]
Technical modifications to the appliance only by
agreement and approval of the manufacturer.
Do not obstruct the temperature display, safety in-
structions or the rating plate [see } Chapter 3.2.1].
WARNING
Danger of tilting of the unit.
Persons may become trapped.
§ Remove the transport frames only when in
the stable and final installation position.
§ In the event of questions, contact the
maintenance service [see } Chap-
ter 11.3.2].
§ Do not climb onto or into the appliance.
Damage to the refrigerant circuit.
Flammable refrigerant can escape and cause
an explosive gas/air mixture. Risk of fire.
§ Do not obstruct the ventilation openings in
the appliance housing. Use only original
accessory parts.
§ Only install the appliance in well-ventilated
rooms.
§ If the appliance is installed in cellars, en-
sure that there is sufficient ventilation.
§ Ducts and wall bushings must be sealed
underneath and behind the appliance to
protect against fire.
§ The operator must not drill into the appli-
ance or carry out any other work on it.
§ Do not crush or bend pipes.
CAUTION
Material breakage.
Falling hazard. Cuts.
§ Do not climb onto or into the appliance.
440195_1_0521
§ Do not apply any load to the lids.
Heavy device parts.
Hands may become trapped.
§ During setup and installation, pay atten-
tion to fingers and hands.
§ Wear protective gloves.
NOTICE
Material and property damage due to conges-
tion of the warm exhaust air (heat accumula-
tion).
§ The exhaust air must be able to escape freely at
the rear of the unit.
§ To ensure good air circulation, maintain minimum
distances to surrounding walls and other appli-
ances.
§ For block setup, the ventilation openings of the de-
vice cover must not be blocked.
§ Superstructure may only be installed in agreement
with the manufacturer. Minimum distance 100 mm
(3,9 in).
Material and property damage in the event of
faulty setup.
§ Install the appliance in a stable operating position
(horizontal alignment).
§ Only set up the unit on its pre-assembled sliding
feet.
§ Do not pull or push on the cover frame and the
glass side panels when setting up.
§ To ensure good air circulation, maintain minimum
distances to surrounding walls and other appli-
ances.
§ Do not expose the appliance to direct heat radia-
tion at the place of installation, e.g.:
- Sunlight
- Artificial external light sources
§ Do not expose the appliance to the direct influence
of air conditioning and ventilation systems at the
place of installation.
§ Do not install the appliance outdoors.
§ Do not attach any thick insulating materials to the
outer walls. Advertisement signs may only be
stuck on as thin film.
Pull or push the unit by the foamed parts.
DO NOT pull or push the unit on the glass panels with
cover frame.
Fig. 7: Glass panels with cover frame (1), foamed parts (2)
Minimum spacing for individual setup
All around: 100 mm (3.9 in)
Setup and installation | 8
1
2
41 / 104