OPERATING SPECIFICATIONS

Flow Rate:
Pressure Range:
Temperature Range:
Capacity:
Rating:
*Not tested or certified by NSF
PRECAUTIONS
Carefully read and follow instructions.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the system.
California Proposition 65 Warning:
This product contains chemicals know to the State of California to cause cancer or
birth defects or other reproductive harm.
Filter must be protected against freezing, which can cause cracking
of the filter and water leakage.

INSTALLATION INSTRUCTIONS

The system and installation must comply with all state and local laws and
regulations.
1. Turn off the cold water supply.
2. Locate an easily accessible section of tubing between the shut off
valve and the refrigerator. Use an 8-foot coil (3 coils, approximately
10-inch diameter) of plastic or copper tubing between the outlet
of the filter and the refrigerator. Determine the length of plastic or
copper tubing needed to connect the inlet and outlet of filter. Leave
a minimum of 2-inches of pipe after shut-off valve in case pipe must
be re-cut at a later time. Deburr ends of remaining pipe with a file.
3. Cut tubing using a tube cutter - smooth out the sharp edges of the
cut tubing with a file or steel wool. Do not cut tubing on an angle.
Tubing cut on an angle may leak during service.
NOTICE: Install the unit with the directional arrow in line with the
water flow. See Figure 1.
4. Insert supply side tubing (1/4-inch copper or plastic tube) into the end
of filter on the supply side. Push firmly until the tubing bottoms out
(approximately 5/8-inch).
5. Turn the water supply on. Hold the filter over a bucket and flush until
water runs clear. TURN THE WATER OFF.
6. Repeat Step 4 on the refrigerator side of the filter. Make sure the
tubing is firmly pushed to the bottom of the fitting.
7. Turn the water supply back on and check for any leaks.

FILTER REPLACEMENT

1. Turn off the cold water supply to the filter.
2. Remove the tubing from the ends of the unit.
See Figure 2.
3. If tubing ends are rough or deeply scratched, repeat Step 3 under
"Installation Instructions."
4. Install the new filter. Refer to Steps 4 through 7
under "Installation Instructions."
NOTICE: Be sure unit is installed in the direction as shown in Figure 1.
0.5 gpm
25-125 psi
40°F-100°F
3,900 gallons*
15 microns* (nominal)
ENGLISH
NOTES:
For cold water use only.
The contaminants or other substances removed or reduced by this water
treatment device are not necessarily in your water. Ask your local water
municipality for a copy of their water analysis, or have your water tested by a
reputable water testing lab.
Filter cartridge life varies depending on filter type, usage, and water conditions.
The replacement filter cartridge used with this system has a limited service life.
Changes in taste, odor, or flow of the water being filtered indicate that the
cartridge should be replaced.
Use only OMNIFILTER replacement cartridges.
This installation must comply with all applicable state and local regulations.
After prolonged periods of non-use, such as a vacation, it is recommended that
the system be flushed thoroughly. Let water run for 5-6 minutes before using.
An activated carbon cartridge may contain a small amount of carbon fines (very
fine black powder). A new cartridge, after installation, should be flushed with
sufficient water to remove the fines before using the water.
Wear safety glasses during installation.
1
2
Inlet Port
(Collet Fitting–
Outlet the same)
To the Refrigerator
From the Water Supply
Push tube in to assemble
Push in collet ring and
Collet Ring
pull tube to remove
Inlet Water Line
2