UV cabinet
Warnings

Preventive measures

 Attention: before using the machine, please
completely read this operating manual.
 Keep this operating manual properly for fu-
ture.
 Do not allow children or non-qualified per-
sonnel handling the unit.
 Do not touch the unit or the power cord with
wet hands.
 Unplug the unit in case of storm and when
you are not going to use it for a long time.
 Place the unit in a dry place, away from dust
and water splashes.
 Do not pull, twist or fold the power cord ex-
cessively.
 Do not wet the unit; do not use chemical
products to clean it.
 WARNING: to prevent electric shock haz-
ards, connect the unit to a proper power
source (grounded 230 V, 50/60 Hz).
 The machine features a precision circuit. Pre-
vent fortuitous impacts and stresses that
could cause mechanical damage.
 Do not introduce potentially explosive sub-
stances.
 Remove any dirt or water from the cable
connection.
 Unplug the appliance immediately if you de-
tect noise, odor or smoke.
 Install the product away from heat sources.
 Do not use the appliance in particularly hu-
mid places, or near flammable materials (al-
cohol, solvents, etc.).
 Do not use the machine with products differ-
ent than defined in the intended use.
 To prevent accidents, be cautious when using
the unit.
 Always keep the device in idle mode, except
when mixing.
 Choose a flat and firm surface to place the
unit, away from heat or vibration sources.
 Do not dismount, repair or modify the ma-
chine.
 If you find a defective component or a prob-
lem do not use the machine.
 Contact us for questions or detailed trouble-
shooting information.
NOTE: Carefully read this manual. It contains impor-
tant safety information in the installation, use
and maintenance. If the equipment is used in a
manner not specified by the manufacturer, the
security provided by the equipment may be
compromised.
Thank you for purchasing our UV disinfection cabinet.
Please read these instructions for use carefully before
using the product.

Operating principle

The germicidal properties of ultraviolet light are widely
known. It is known that UV light with wavelength ran-
ges between 185 and 254 nanometers is able of interac-
ting with the DNA of germs, causing their death in a
very short time.
For its part, light with a wavelength of 185 nanometers
is able of ionizing the oxygen in the air, generating ozo-
ne (O3). This gas has widely proven germicidal proper-
ties. As a gas, it can be introduced through all the cracks
of the object to be disinfected. On the other hand, —and
due to the low concentration— the ozone gas generated
is not harmful for health.
Disinfection range
The device is suitable for the following microorganisms:
bacteria, microbacteria, viruses (different types), spores,
chlamydia, organisms of the fungus group, etc.
Operation
1. Place the appliance on a stable surface or hanging
vertically from the wall.
2. Put the objects to be sterilized into the chamber
(clean and dry).
3. Select the sterilization time between 0 and 999 mi-
nutes:
-
Press the "Select" key to select a digit.
-
Press the "Forward" key to change that digit.
4. Make sure the door is properly closed.
5. Press the "Power" key to start sterilization.
6. The lamps will start. At the end of time they will
turn off by themselves.
7. Press the "Power" key again if you want to interrupt
the cycle.
8. The chamber is equipped with a door open control
and will turn off if the door is opened.
For reference, the mean sterilization time is usually 15
minutes.