Descargar Imprimir esta página

BWT AQA drink WD CO2 Instrucciones De Montaje Y Manejo página 6

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 10
2. CONNECTING GAS PRESSURE REDUCER
1. Connect a food-safe hose to the existing ¼" metal push-fit connection on the gas pressure reducer.
If necessary, replace the ¼" metal push-fit connector that has already been screwed in with the
5/16" metal push-fit connector. Depending on the available installation space, the appropriate elbow
connector (2 or 3) can be used to attach the hose to the CO
or to connect it at 90° to the inlet of the water dispenser system.
2. Connect the food-safe hose at the CO
3. Fix the appropriate circlips (4 or 5) at every connection.
4. Open shut-off valve (A).
5. Check system for leaks.
EN
3. CALCULATE CO
GAS CONCENTRATION
2
Caution!
For safety reasons, in case of a gas leak, the CO₂ concentration in the room must not exceed 3%.
During the installation of the CO
gas cylinder, it is recommended that the maximum CO
2
content should be determined beforehand in accordance with the available room size or available
room volume.
10
outlet of the pressure reducer at 90°
2
inlet of the water dispenser system.
2
The following overview shows the required room volumes for common CO
CO
gas concentration in the room (vol. %) =
2
CO
cylinder
2
Content
content
(kg)
2
3
5
6
cylinder
2
10
If the calculated gas concentration of 3% is exceeded, the following measures are possible:
» Use of a smaller CO
» Increase in the size of the room (e. g. by removing doors)
» Installation of a CO
» Installation of technical ventilation
The CO
gas concentration is calculated as follows:
2
(calculated on the basis of a CO
gas density of 2 kg/m³):
2
Gas volume or cylinder content (m³)
Room volume (m³)
Content
Room volume required for
(m
3
)
(l)
safety reasons (m³)
1
1,000
35
1.5
1,500
51
2.5
2,500
85
3
3,000
105
5
5,000
170
gas cylinder
2
gas warning device in accordance with DIN 6653–2
2
cylinder sizes
2
Room surface area required for
safety reasons (m²)
(for a room height of 2.5 m)
EN
13.5
14.4
34
41
68
11

Publicidad

loading