Thermal Cut-Out Reset

This appliance is fitted with a Thermal Cut-Out safety feature. Should the temperature exceed safe levels
the appliance will automatically cut power.
The Safety Cut-out switch is located on the underside of the appliance. To reset the appliance:
Empty the appliance and allow to cool.
1.
Press the reset button until it clicks.
2.
WARNING: Ensure the appliance has cooled down and is empty before resetting the
switch, as it may need to be tipped slightly to gain access to the switch.
The appliance is now reset and can be used as normal.
3.
Cleaning, Care & Maintenance
Always turn off and disconnect the appliance from the power supply before cleaning.
Use soapy water and a damp cloth to clean the exterior of the appliance.
Dry thoroughly after cleaning.

Descaling

In hard water areas lime scale can build up within the appliance after prolonged use. A buildup of scale can
reduce the efficiency of the appliance and cause damage to the element.
To descale the appliance follow the instructions provided with any suitable descaler.
Note: Always flush out the system thoroughly after descaling.
Caterlite recommend that this appliance is descaled every 3 months or more frequently
in hard water areas.

Troubleshooting

Fault
The unit is not
working
Power light comes on
but water does not
reach temperature
Heatup time has
increased
The tap is leaking
3
Probable Cause
The unit is not switched on
Plug and lead are damaged
Fuse in the plug has blown
Power supply
Internal wiring fault
Thermostat fault
Buildup of scale
The tap has become loose
Action
Check the unit is plugged in correctly and
switched on
Call Caterlite agent or qualified technician
Replace the plug fuse
Check power supply
Call Caterlite agent or qualified technician
Call Caterlite agent or qualified technician
Descale the appliance
Tighten the tap handle