1.
Do not pump flammable or explosive liquids such as oil, gasoline, kerosene, ethanol, etc. Do not use in the presence of
flammable or explosive vapors. Using this pump with or near flammable liquids can cause an explosion or fire, resulting
in property damage, serious personal injury, and/or death.
2.
Disconnect power (unplug) the primary sump pump before installing, working on, or servicing the backup sump pump.
3.
The backup sump pump requires a city water source with a minimum pressure of 40PSI. The inlet pipe should be at
least 3/4" in diameter.
4.
Clean the backup sump pump regularly.
5.
Release all pressure and drain all water from the system before servicing any component.
6.
Secure the discharge line before starting the pump. An unsecured discharge line will whip, possibly causing personal
injury, and/or property damage.
7.
Wear safety goggles at all times when working with pumps.
8.
Failure to comply with the instruction and designed operation of this unit may void the warranty. ATTEMPTING TO USE
A DAMAGED PUMP can result in property damage, serious personal injury, and/or death.
9.
Know the pump and its applications, limitations, and potential hazards.
10. Secure the pump to a solid base. This will aid in keeping the pump in a vertical orientation. This is critical in keeping the
pump operating at maximum efficiency. It will also help prevent the pump from clogging resulting in premature failure.
11. Periodically inspect the pump and system components to ensure the pump suction screen is free of mud, sand, and
debris
12. Follow all local electrical and safety codes, along with the National Electrical Code (NEC). In addition, all Occupational
Safety and Health Administration (OSHA) guidelines must be followed.
PRE-INSTALLATION
APPLICATION
The backup sump pump is designed for as an auxiliary back-up sump pump for private residences in case of primary
sump pump failure or a power outage. It is not designed for and should not be used as a primary sump pump.
Inlet water
pressure
40PSI
60PSI
GPH of Water @ Total Feet Of Lift
0 ft.
5 ft.
573
495
702
630
2
10 ft.
15 ft.
420
340
545
465