OPERATING INSTRUCTIONS
Translation of the original operating instructions
!
Connector socket for left handpiece
@
Connector socket for right handpiece
#
Mains connection
$
On/Off switch for left handpiece
%
On/Off switch for right handpiece
^
Pilot LED of operating condition of left
handpiece
&
Pilot LED of operating condition of right
handpiece
*
Light spot indicating that the handpiece is
activated
(
Heating element
BL
Feeding roll Waxjet
BM
Drive roll Waxjet
PRODUCT DESCRIPTION
Smartwax duo is an electronically controlled wax
knife with the possibility to connect two handpieces
that can be operated separately.
This unit is suitable for all kinds of modeling and
wax-up work and is unbeatable in combination with
the Waxjet when making full dentures. The con-
tinuous wax supply via the unique feeding mech-
anism of the Waxjet allows the dental technician
to quickly apply a big amount of wax, which helps
to save time.
Each handpiece can individually be set to three
different temperatures. This means utmost user
comfort for the dental technician.
A twist-free and heat-resistant cord connects the
handpieces with the control unit and ensures
comfortable and ergonomic work.
The plug-in connector between the handpiece
shank and the handle with firmly fixed modeling
tip offers easy and safe exchange of the instru-
ments – without burning the fingers. At the same
time, the Smartwax duo handpiece heats up the
instruments very quickly thanks to the special
design of the handpiece and to the good heat
conductivity of the modeling tip.
START-UP
Please check immediately after unpacking if the
unit shows transport damages. If so, please inform
the supplier promptly. After unpacking, the unit
is ready for operation. Please check if the voltage
of the mains adaptor corresponds to the local
mains voltage. If you are uncertain about the
mains voltage used in your country, we recom-
mend addressing to the electric or electronic
trade.
At first, plug in the handpiece cord at the connec-
tor socket of the left handpiece (1) or of the right
handpiece (2) at the housing of the unit. Then,
connect the cable of the mains adaptor to the
mains connection (3) and to the mains voltage.
OPERATION
Each handpiece is switched on separately by
pressing the according On/Off switch (4 or 5).
After switching on the first handpiece, the display
indicates °C or °F. As long as this notice is flashing,
you can choose between °C and °F with the pro-
gram key P.
While heating up, the pilot LEDs (6 and 7) are
flashing, but when the selected temperature is
reached, the LEDs light permanently.
Shortcuts P < or P >:
_ These shortcuts are used to switch between
the left and the right handpiece.
_ With P < you activate the left handpiece.
_ With P > you activate the right handpiece.
The light spot (8) in the display shows which hand-
piece is activated at the moment and to which
handpiece the temperatures indicated belong.
Light spot at left:
_ temperatures indicated in the display belong to
the left handpiece
_ left handpiece can be controlled
Light spot at right:
_ temperatures indicated in the display belong to
the right handpiece
_ right handpiece can be controlled
IMPORTANT: If the pilot LED (6 / 7) is lit, also
the other handpiece is heated and the instrument
is hot! Therefore, if you only work with one hand-
piece, either completely switch off the other hand-
piece at the On/Off switch (4 / 5) or pull the plug
of the handpiece cord out of the connector socket!
Keys < and >:
_ With < you lower the temperature.
_ With > you increase the temperature.
A short push on either one of these keys changes
the temperature by 1 °C. If you push longer, the
temperature first drops or increases slowly, and
then becomes faster (fast mode).