SER30E – SER30 – SER30P
4.2
Learning work times
The control unit can learn the opening and closure work times. To enter learning mode, the control unit must be in stop-closed status.
•
Press the programming key once and release it. The LED lights up with a red steady light.
•
Press the programming key again for approximately 2 seconds until the LED flashes briefly.
•
Within 10s, press the enabled key of the transmitter or close the OPEN contact to activate the motor opening manoeuvre. The control unit
starts to measure the opening work time. At the end of the work time, press the key of the transmitter again or the OPEN key. The motor
stops in standby.
•
Press the enabled key of the transmitter or close the OPEN contact to activate the motor closure manoeuvre. The control unit starts to
measure the closure work time. At the end of the work time, press the key of the transmitter again or the OPEN key. The motor stops in
STOP status and the LED switches off. The procedure is terminated.
While making the manoeuvre, the control unit adds 2 seconds to the set manoeuvre times, to ensure the manoeuvres are completed even in the
event of slow-down due to environmental conditions or wear.
4.3
Programming and deleting radio codes (only for SER30E and SER30)
Dip 3
Dip 4
ON
ON
ON
OFF
OFF
ON
OFF
OFF
The PROG button on the control unit is used to store new codes and delete the entire list of codes.
Programming
•
Power the control unit correctly.
•
Press the PROG button: the red LED lights up to signal that programming is in progress.
•
Make a transmission by pressing the transmitter button associated with the enabled channel.
•
The code is stored. The LED flashes while memorising the code. Afterwards, the LED is lit with a steady light to signal that a new code can
be entered.
•
Store all the transmitters by making a transmission with each one.
•
Afterwards, press the PROG button again to exit the procedure. The LED switches off. Ten seconds after storing the last code, the procedure
closes automatically.
•
The codes stay in the memory even in the event of a blackout.
Total deletion of codes
•
Press and hold down the PROG button until the red LED starts to flash
•
Press button P1 again within 10 sec. to confirm the deletion. The LED flashes rapidly to confirm the deletion.
4.4
Selecting the courtesy light or autonomous flashing light
The output LAMP can operate as a courtesy light or flashing light.
For the "courtesy light", the output is active for 1 minute starting from the beginning of each manoeuvre.
For the "flashing light", the output activates 2 seconds before the beginning of each manoeuvre (pre-flash) and stays active for the duration of the
manoeuvre. An autonomous flashing light with 230VAC power supply must be connected.
Insert the jumper CL/WL in position CL to operate with the "courtesy light".
Insert the jumper CL/WL in position WL to operate with the "flashing light".
4.5
Photocell operation
The photocell has a "safety in closure" function.
During the closure manoeuvre, in modes "STEP-BY-STEP" ,"AUTOMATIC" and "SEMIAUTOMATIC CLOSURE" only, the photocell triggering
generates the motion inversion until complete reopening.
During the opening manoeuvre, in all modes, the photocell triggering has no effect.
In mode "SEMIAUTOMATIC OPENING", the photocell triggering has no effect.
In the absence of a photocell, jump terminals PHO and COM on the terminal board.
In the presence of a photocell, connect the output contact of the photocell to terminals PHO and COM of the control unit so that, with the photocell not
interrupted, the contact PHO – COM is closed.