Robern MT Instrucciones De Instalación página 4

Ocultar thumbs Ver también para MT:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

How to Surface Mount Cabinets
Surface mounted cabinets use the "Z" Mounting Bars to
hold the cabinets. No holes are cut in the wall. Refer to
Figure C on page 3.
Before installing surface mounted cabinets
NOTE:
with an Electrical option, run electrical wire for
cabinet through rough-in hole in wall. See "Wiring
an Electrical Option" on page 7.
1. Each cabinet is shipped with an aluminum "Z" Mount-
ing Bar. Cut this bar approximately 1" (25.4 mm) shorter
than the overall width of your cabinet combination.
It is strongly recommended that a support
NOTE:
similar to that used for a wall-mounted sink be
framed into the wall during construction as shown
in Figure D.
2. Locate and drill three 7/32" (5.6 mm) holes through the
indent line on the mounting bar into the wall. Be sure
the mounting bar is level (see Figure D). Use the #10
X 2" (50.8 mm) SMS/Wood screws provided to attach
the mounting bar to the wall. If no furring strip has been
installed, use the supplied plastic anchors, making sure
that each cabinet is supported by at least 3 anchors.
See instructions below.
3. Three "Z" clips are supplied for the top of each cabinet.
You can pre-drill 7/32" (5.6 mm) holes for
NOTE:
"Z" clips at the predetermined location. If there
is no support in the wall, use the supplied plastic
anchors.
Slide the three "Z" clips into the screw channel at the
top of the cabinet; be sure that the "Z" clips lock into the
e sure that the "Z" clips lock into the
grooves
grooves. Lift the cabinet and place the cabinet onto the
mounting bar.
When using an Electrical option, fi rst
NOTE:
remove outlet shelf and pull rough-in wire from
wall through wire access hole in back of cabinet
as described in "Wiring an Electrical Option" on
page 7.
4. Using the #10 X 2" (50.8 mm) SMS/Wood screws
provided, attach the top of the cabinet to the wall
through the "Z" clips and into the wall as shown (see
Figures D and E).
5. Mount the doors following the instructions supplied
with the hinge and shown in Figure M on page 8.
Open and close the doors to check their operation.
6. If using an Electrical option, plug the cord for the
Electrical option door into the outlet shelf. Check for
proper operation of electric and the defogger and/or
night light. See "Adjustments and Maintenance" on
page 8 for help.
7. Install shelves as shown in "Final Assembly" on
page 8.
209-1090 MP and MT Cabinets 03/29/07
Figure D
#10 X 2" (50.8 mm)
SMS/WOOD SCREW
LOCATE MOUNTING BAR
TO CLEAR SINK FAUCETS
BY AT LEAST ONE INCH
(25.4 mm)
Figure E
WARNING: Make sure
that the "Z" clip slides
completely, and is locked
into, the screw channel.
Failure to do this can
result in property
damage or bodily harm.
3 TOP
"Z" CLIPS
TOP OF CABINET
FRAME MEMBER
SLIDE THE TOP
"Z" CLIPS THROUGH
THIS SCREW
CHANNEL FROM
CENTER OPENING
Poly-set Anchor Instructions
for Hollow Walls
1. Drill
9/32" (7.1 mm)
hole and insert anchor
until fl ange is fl ush.
2. Insert #10 X 2" (50.8 mm) SMS/Wood screw
through bracket and anchor. Continue to turn
screw to fully expand the anchor.
4
MOUNTING BAR
1"
(25.4 mm)
1" X 3"
(25.4 mm x 76.2 mm)
FURRING STRIP
BEHIND WALL
BOARD OR TILE.
LOCATED AT
CENTER OF
BOTTOM EDGE
OF CABINET
OVERALL DIMENSION
MT = 30" (762 mm)
MP = 39 3/8" (1000.1 mm)
MOUNTING BAR

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mp

Tabla de contenido