FILTER CARTRIDGE REPLACEMENT INSTRUCTIONS
To reduce the risk associated with property damage due to water leakage:
• The disposable fi lter cartridge MUST be replaced every 6 months, at the rated capacity or sooner if
a noticeable reduction in fl ow rate occurs.
1. AP11T: Shut off inlet and outlet valves, depress pressure relief button on top of filter head to relieve pressure in filter.
AP101T, AP141T and AP102T: Turn valve handle to "OFF" position. The inlet and outlet lines are now closed off from
the filter chamber and the pressure has been released at the built-in vent port.
2. Unscrew housing to the left from the filter head and remove cartridge, emptying water from housing.
3. Clean and inspect all components. Lubricate o-ring with a silicone based lubricant or water. Do not use Petroleum
Based Lubricants. Replace o-ring seal if there is visible damage.
4. Install new cartridge into housing, over centering post if you have an AP102T two-high unit.
5. Place lubricated o-ring on the housing. Screw housing to the right firmly onto head until a definite stop is felt and car-
tridge is sealed. Hand tight is sufficient. However, be sure not to overtighten or force housing.
6. A11T: Turn on inlet valve and depress pressure relief button until air is purged from filter. Release button and turn on
outlet valve.
AP101T, AP141T and AP102T: Turn valve hand to the "ON" Position. Wait until filter is filled with water and check for
leaks. Open and close the valve once to released trapped air. Allow a slight pause in the "OFF" position. Replace car-
tridge when there is a decided drop in water flow at the faucet or tap.
• DO NOT leave valve-in-head models in "OFF" position for an extended period of time or use as a substitute
for main water line valve if line must be shut off for servicing.