Saladette
6.5 Placing out of operation
When the appliance is not being used:
Pull the plug from the socket.
Clean the appliance.
Allow the air circulation into the cooling cell.
Cover the appliance with a cloth that is permeable to air.
Store the appliance in a closed room.
For the storage mind the environment conditions:
Storage temperature: -25 °C to +55 °C
Air humidity: 30% to 75%
7
Maintenance/Cleaning
Unplug the appliance before every maintenance or cleaning.
7.1 Cleaning
Clean the appliance every week.
Switch off the appliance before cleaning it.
Do not use aggressive cleaning stuff.
Do not use a solvent for the cleaning.
To clean the appliance:
Use a bacteria killing product for the container and all the inner parts.
Wipe the plastic parts with a moist cloth.
Dry the appliance with a soft and clean cloth.
Clean the condenser every week
To clean the condenser:
Switch off the appliance.
Pull the plug from the socket.
Unscrew the screws on the protection grid.
Remove the dust with a brush and a vacuum cleaner
on the fins of the condenser.
on the filter.
Screw the protection grid again.
To contact our customer service please visit www.servicevega.com
17