air supply
Tools of this class operate on a wide range of air pressures. It is
recommended that air pressure of these tools measures 90 PSI at the tool
while running free. Higher pressure and unclean air will shorten tool life
because of faster wear and may create a hazardous condition.
Water in the air line will cause damage to the tool. Drain the air tank daily.
Clean the air inlet filter screen on at least a weekly schedule.
The recommended hook-up procedure can be viewed in Figure 1.
The air inlet used for connecting air supply, has standard 1/4" NPT
American Thread.
Line pressure should be increased to compensate for unusually long air
hoses (over 25 feet). Minimum hose diameter should be 3/8" I.D. and fittings
should have the same inside dimensions.
luBricaTion...
Lubricate the air motor daily with quality air tool oil. If no air line oiler is used,
run a 1/2 ounce of oil through the tool. The oil can be squirted into the tool
air inlet or into the hose at the nearest connection to the air supply, then run
the tool. The amount of oil to be used is 1/2 ounce. Overfilling will cause a
reduction in the power of the tool.
Troubleshooting for the head of the rivet gun
1. Make sure that there is no air flow going to the Rivet Gun.
2. Use the spanner to remove the head from the frame. (Fig. 1)
3. Use the spanner to remove the Jaw Housing, Jaws, Jaw Pusher, and the Pusher Spring. (Fig. 2)
4. Thoroughly clean the inside of the Frame Head. (Fig. 3)
5. Use a light gauge machine oil to lubricate the parts shown in figure 4.
6. Re-assemble the Rivet Gun and check the length of the Rivet Gun Head by using the spanner as shown in figure 5.
SE200
SE200 3/16" Air Hydraulic Rivet Gun
Fig. 1
Fig. 4
TrouBleshooTing
Other factors outside the tool may cause loss of power or erratic action.
Reduced compressor output, excessive drain on the air line, moisture or
restrictions in air pipes or the use of hose connections of improper size or
poor condition may reduce air supply. Grit or gum deposits in the tool may
cut power and may be corrected by cleaning the air strainer and flushing
out the tool with gum solvent oil or an equal mixture of SAE #10 oil and
kerosene. If outside conditions are in order, and the tool continues erratic
action or low power, disconnect tool from hose and contact your nearest
authorized service center.
Fig. 2
Fig. 5
3
fig. 1
Fig. 3