What's in the Box
1
Standard Items
Intellex or Intellex LT Unit
USB/232 Adapter
1 Network Client Disk
Installation Instructions
(Premier only)
and Addenda
1 Manuals Disk
2 Recovery Disks
Mouse
2 Power Cords
Alarm Connectors
(16 Camera
only)
Reset Tool
2
Required Items
Optional Accessories
Rack Mount Kit
VGA or Flat Panel Monitor
SCSI External DAT Drive
Cameras and BNC Cables
1 to 4 or 1 to 8 Text Data Port
Expander (Premier Only)
USB Sensornet Adapter
Contenu de la boîte
1
Eléments standards
Unité Intellex ou Intellex LT
USB/232
Instructions d'Installation et
Adaptateur (Pre-
supplément
mier uniquement)
1 Manuels Disque
2 Disques de
Récuperation
2 Cordons d'alimentation
Connecteurs d'alarmes
(Caméra 16 uniquement)
Outil de réinitialisation
2
Eléments necessaries
Accessoires facultatifs
Kit de montage en rack
Moniteur VGA ou écran plat
Lecteur DAT externe SCSI
Caméras et câbles BNC
Extension (Premier uniquement) de
port de données texte 1 à 4 ou 1 à 8
Adaptateur USB-Sensornet
INTELLEX
3
Rear Panel Connectors
1. Connect the Mouse
Connect the green PS/2 adapter
to the green unit connector.
Mouse Pad
BNC Connectors:16 Channel
Miscellaneous
4. Connect Cameras to BNC Connectors
Accessories
Pack
5. Set Video Termination
16 Camera Units:
Set video signal termination to 75 Ohms if needed via the Intellex Setup screen.
When the video signal is looped to multiple units through the Camera Out, set the
video signal to Hi-Z on the Intellex Setup screen, then set the last unit to 75 Ohms.
Alarm Adapter
4 and 8 Camera Units:
(4 and 8 Camera)
Default Installation: leave the BNC switches set to Infi nity and use the Intellex Setup
screen to set the termination to 75 Ohms.
75 Ohm Termination: with the Intellex power off , set the BNC switches to 75 Ohms and
use the Intellex Setup screen to set the termination to Hi-Z.
6. Connect the power to the Intellex.
Guide de réglage rapide de l'INTELLEX
3
Connecteurs du panneau arriére
1. Connecter la souris
Connectez l'adaptateur vert
PS/2 au connecteur vert de
l'unité.
1 Disque Network Client
Connecteurs BNC : Canal 16
Tapis de
souris
Accessoires
4. Connecter les caméras aux connecteurs BNC
Souris
divers
5. Défi nir la terminaison vidéo
Unités à 16 caméras :
Réglez la terminaison du signal vidéo sur 75 Ohms (si besoin) par l'écran Réglage d'Intellex.
Si le signal vidéo est bouclé sur plusieurs unités via la sortie caméra, confi gurez le signal vidéo
à Hi-Z dans l'écran de confi guration Intellex, puis défi nissez la dernière unité à 75 Ohm.
Adaptateur d'alarme
(Caméras 4 et 8)
Unités à 4 et 8 caméras :
Installation par défaut : Laissez les commandes BNC sur Infi nité et utilisez l'écran
Réglage de l'Intellex pour régler la terminaison sur 75 Ohms.
Terminaison de 75 Ohm : L'Intellex étant désactivée, défi nissez les commandes BNC
sur 75 Ohms et utilisez l'écran Réglage d l'Intellex pour defi ner la terminaison sur Hi-Z.
6. Branchez l'alimentation sur l'Intellex.
®
Quick Setup Guide
2. Connect the VGA Main Monitor to the blue
female connector behind the ribbon cable,
then power up the monitor.
VGA
Video and Alarm
Connectors
BNC Connectors: 4 and 8 Channel
3. Connect the optional Touch Tracker Dome
Controller to the 9-pin serial connector.
Note: power up the VGA or Flat Panel Monitor
before you power up the Intellex.
It is critical that you select the appropri-
ate time zone in the Windows Operating
System and the appropriate video format
for your location.
2. Connectez l'écran VGA principal au
connecteur femelle bleu derrière le
câble en ruban, puis allumez l'écran.
VGA
Connecteurs
d'alarme et du vidéo
Connecteurs BNC : Canaux 4 et 8
3. Connectez le contrôle tactile de dôme au
connecteur sériel à 9 broches.
Remarque : allumez l'écran VGA ou plat avant
d'allumer l'Intellex.
Il est d'importance critique que vous sé-
lectionniez le fuseau horaire correct sous
le système d'exploitation Windows, ainsi
que le format vidéo approprié pour votre
région.
4
Power Up & Test
Note:
VGA Monitor and any peripherals should be powered up before the Intellex unit
is powered up.
Be sure to use an Uninterruptible Power Supply (UPS).
Be sure to use surge protection for power supply and provide appropriate
grounding.
The Intellex powers up automatically when it is connected to the power source. Video infor-
mation should display on the VGA monitor. The power indicator on the front panel illuminates
when the Intellex powers up.
If the unit does not power up automatically:
Insert the Reset Tool into the top pinhole on
the front panel and push gently on the power
switch.
To shut down the unit:
Use the mouse to select Utility, Shutdown
from the user interface of the VGA Main Monitor.
To power up the unit again:
Insert the Reset Tool into the top pinhole on the front panel and push gently on the power
switch.
Caution! The lower pinhole is used to reset the unit. This is not normally
needed and could cause damage to the software on the hard disk.
LEDs
Power Indicator
Green = ON
5
Results
The Intellex should be recording live video and displaying the information on the
monitor. The Power LED is illuminated and the fan is running.
Is the Intellex functioning as described?
YES!
Shut down the unit and continue to install alarms and other accessories, as needed, using
the Intellex Installation and Confi guration Guide and the User Guide. Refer to the Manuals
CD for the Installation and Confi guration Guide and the User Guide.
NO!
If your unit powered up, shut down by using the mouse to select Utility > Shutdown from the
user interface. If the user interface is not available on the monitor, insert the Reset Tool into
the top pinhole of the front panel and push gently on the power switch to shut down the unit.
Then check the following:
1.
Connections
Cables, cords, and other connectors
4.
2.
Termination settings
5.
Monitor(s)
3.
Cameras
Power up the unit, listen for the fan to start, and watch for the Power LED (Green = ON).
If you have checked all these items and the unit fails to power up, or you repowered
your unit and the unit still fails to operate properly, please contact your Tyco/Video
representative.
© 2009 Tyco International Ltd. and its Respective Companies. All Rights Reserved
®
4
Mise sous tension et test
Remarque :
Le moniteur VGA et autres périphériques doivent être mis sous tension avant
l'unité Intellex.
Assurez-vous d'utiliser une unité d'alimentation ininterruptible (UPS).
Il faut utiliser une protection contre les surtensions et une mise à la terre appropriée.
L'Intellex démarre automatiquement dès qu'il est connecté à l'alimentation. Des informations
vidéo devraient être affi chées à l'écran VGA. Le voyant d'alimentation sur le panneau frontal
s'allume lorsque l'Intellex démarre.
Si l'unité ne s'allume pas automatiquement :
Insérez l'outil de réinitialisation dans l'orifi ce
supérieur du panneau avant et appuyez douce-
ment sur la commande d'alimentation.
Pour éteindre l'unité :
Utilisez la souris pour sélectionner Ulitiaire,
Fermez depuis l'interface utilisateur du moniteur
principal VGA.
Pour remettre l'unité sous tension :
Insérez l'outil de réinitialisation dans l'orifi ce supérieur du panneau avant et appuyez
doucement sur la commande d'alimentation.
Attention! L'orifi ce inférieur est utilisé pour réinitialiser l'unité. Cette opération
n'est normalement pas nécessaire et risque d'endommager le logiciel
sur le disque dur.
Voyants DEL
Indicateur d'alimentation
Vert = ON (Allumé)
5
Résultats
L'Intellex devrait capter de la vidéo en direct et affi cher ces informations à
l'écran. La LED d'alimentation est allumée et le ventilateur tourne.
L'Intellex fonctionne-t-il comme décrit ?
OUI !
Éteignez l'unité et continuez à installer des alarmes et autres accessoires, selon vos besoins,
en vous aidant du Guide d'installation et de confi guration Intellex et du Guide de l'utilisateur. Re-
portez-vous aux CD des manuels pour le Guide d'installation et de confi guration et le Guide de
l'utilisateur.
NON !
Si votre unité a démarré, arrêtez-la en cliquant avec la souris sur Utilitaire > Arrêt dans
l'interface utilisateur. Si l'interface utilisateur n'est pas disponible à l'écran, insérez l'outil de
réinitialisation dans le trou supérieur de panneau frontal et appuyez doucement sur le com-
mutateur d'alimentation pour éteindre l'unité. Vérifi ez ensuite les éléments suivants :
1.
Connexions,
4.
Câbles, cordons et autres connecteurs,
2.
5.
Moniteur(s).
Paramètres de terminaison,
3.
Caméras,
Mettez l'unité sous tension, écoutez le ventilateur se mettre à fonctionner et regardez le
voyant de marche/arrêt passer au vert (ON).
Si vous avez vérifi é tous ces éléments et que l'unité ne démarre pas, ou que vous avec
rebranché votre unité mais que celle-ci ne fonctionne toujours pas correctement,
veuillez contacter votre représentant Tyco/Vidéo.
© 2009 Tyco International Ltd. and its Respective Companies. All Rights Reserved
Power
Reset (not
Reset
normally needed)
Tool
Record Indicator
Amber = Recording
Alarms Indicator
Red = Alarm State
3_2FP_1
8200-2640-21 A0
Tension
Réinitialisation
Outil de Réini-
(normalement
pas nécessaire)
tialisation
Indicateur d'enregistrement
Ambre = Enregistrement
Indicateur d'alarmes
Rouge = En alarme
3_2FP_1
8200-2640-21 A0

Publicidad

loading

Resumen de contenidos para American Dynamics INTELLEX

  • Página 1 When the video signal is looped to multiple units through the Camera Out, set the video signal to Hi-Z on the Intellex Setup screen, then set the last unit to 75 Ohms. Shut down the unit and continue to install alarms and other accessories, as needed, using the Intellex Installation and Confi guration Guide and the User Guide.
  • Página 2 Apáguelo y continúe instalando las alarmas y demás accesorios, según sea necesario, con del conector Salida de cámara, confi gure la señal de vídeo en Hi-Z en la pantalla de con- la Guía de instalación y confi guración de Intellex y la Guía del usuario. Consulte los manu- Conectores de alarma fi guración de Intellex, luego confi gure la última unidad para 75 ohmios.