Descargar Imprimir esta página

Comelit 1456 Manual Tecnico página 6

Ocultar thumbs Ver también para 1456:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 10
WARNINGS
• Install the equipment by carefully following the instructions given by the manufacturer and in compliance with the standards in force.
• All the equipment must only be used for the purpose it was designed for. Comelit Group S.p.A. declines any responsibility for improper
use of the apparatus, for any alterations made by others for any reason or for the use of non-original accessories or materials.
• All the products comply with the requirements of Directive 2006/95/EC (which replaced Directive 73/23/EEC and subsequent
amendments) as certified by the CE mark they carry.
• Do not route the riser wires in proximity to power supply cables (230/400V).
• Installation, mounting and assistance procedures for electrical devices must only be performed by specialised electricians.
• Cut off the power supply before carrying out any maintenance work.
Art. 1456 / 1456S is an apartment gateway that:
Can be used to check the video entry phone
system via tablets and smartphones on which the
free ComelitViP Remote App has been installed.
This function can be performed locally over Wi-
Fi, or remotely over 3G (or higher) networks.
Can
(depending
limitations) be used to manage up to 15
slave devices (including door entry monitors,
smartphones,
tablets
simultaneous audio/video streams.
Allows "intercom" communication between each
of the 15 devices served.
Allows remote configuration via a Web Page.
In the master version (Art. 1456), does not require
door entry monitors to be connected.
Description of Art.1456 Art.1456S
√ See fig. 1, page 2.
1. Ethernet port for ViP system riser input (default
addressing: Autoip).
2. Dip switches for the procedures "Reboot with
predetermined network settings" and "Restoring
factory settings".
3. Power supply input via Art. 1441, Art. 1441B.
4. CV1 and CV2 for setting port HOME2 (see fig.
2, page 2).
5. CV3 and CV4 for setting port HOME3 (see fig.
2, page 2).
6. HOME4 NON POE Ethernet port for PC or
router connection (default: Static IP address
192.168.1.200, netmask 255.255.255.0).
7. HOME3 POE settable Ethernet port NON POE
(default:
Static
IP
netmask 255.255.255.0).
8. HOME2 POE settable Ethernet port
POE (default: Static IP address 192.168.1.200,
netmask 255.255.255.0).
9. HOME1 Ethernet port POE (default: Static IP
address 192.168.1.200, netmask 255.255.255.0).
6
on
available
bandwidth
and
PCs)
with
address
192.168.1.200,
NON
Configuration of Art.1456 Art.1456S
√ This operation requires a PC loaded with
the software ViP Manager version 2.3.0 or
later (downloadable from the website www.
comelitgroup.com).
√ An active internet connection is also required.
√ For configuration details, please download
the full manual by searching for art. 1456 /
4
1456S on the website www.comelitgroup.
com or decoding the following QR code:
Art. 1456S requires an internal unit assigned
to a master monitor.
Connection
„ Article 1456/1456S has 2 network interfaces,
HOME and VIP SYSTEM, labelled for easy
identification,
separately to meet different system requirements.
Depending on the type of system, connect the
devices as shown in the following figures: fig.
3-4, page 3-4.
Multi-residential system (fig. 3 page 3)
Take particular care with regard to the network
interface settings and do not configure
interfaces ViP SYSTEM and HOME with the
same addresses or similar parameters: each IP
address must be unequivocal, the addresses
of the interfaces ViP SYSTEM and HOME must
not belong to the same subnet.
Kit system (fig. 4 page 4)
All system devices form part of a single network,
so it it is only necessary to configure interface
HOME.
In this case, DO NOT alter the configuration of
interface VIP SYSTEM.
which
can
be
configured

Publicidad

loading

Este manual también es adecuado para:

1456s