ENGLISh
INSTALLATION
The device must be installed inside an electric panel or cabinet.
CONNECTION Of ThE pOWER SUppLy UNIT
Power supply
110-230V~
DESCRIpTION Of ThE TERMINALS
PRIM
Input voltage 110-30V~
}
GND
Output voltage for video door phone
33V
TEChNICAL DATA
Power supply:
Power:
Secondary output:
Power dissipated after after 1 hour of functioning:
Dimensions (WxDxH):
Purpose:
DS17-01B
Installation on DIN bar (6 x 18mm modules)
PRIM
1
2
AI
To the video door phone
AI
GND 33V
GND
33V
33 Vdc 0.6 A continuous (+0.6 A intermittent)
108 (6 DIN modules) x 90 x 61mm
power supply unit for video door phone systems
100/250 Vac 50-60 hz
max. 50W
Max 50Wh (180 kJ)
3