GENERAL INFORMATION
The 03212 is a photoelectric smoke alarm, it accords with ISO/DIS 12239 standard, it has much effect to
detect smoke.
IMPORTANCE! PLEASE READ THE MANUAL CAREFULLY AND KEEP IT the manual includes impor-
tant information related to it's operation, to ensure your safety, you should install one alarm in every room at
least, don't open the alarm easily to avoid bad effect.
SPECIFICATIONS
Power source: 9V DC
Static current: <6.5uA
Alarm current: 10mA
Alarm volume: >85db (3m)
Low voltage alarm: 5.5V ~ 6.2V
Working temperature: -5ºC~+40ºC
Working humidity: <93% RH
THE PLACE FIT TO INSTALL
- In the bedroom and corridor you should install one in every bedroom at least.
- On the top of the stairway, because where is the routeway for escape.
. You had better install alarm in every compartment on every floor, including attic and basement.
- Install one beside the elecronic appliance.
- Install it in the middle of the ceiling, because smoke always spread upwardly.
- If you can't install it in the middle, it should also be installed beyond 10cm away from the wall (see
diagram1).
- If you install it on the wall, it should be 10~30,5cm away from the ceiling at least (see diagram2).
- When your room's length is beyond 9m, you should install more than one alarm.
- In the room with oblique roof (diagram 2) the alarm should be below 0,9m away from the top.
- In movable house, the alarm must be 10~30,5cm away from the ceiling, because the kind of house has no
isolation layer.