S p e c i f i c a t i o n s
10

SPECIFICATIONS

Size................................................................................7.5" W x 4.0" H x 7.2" D
(19.1 cm x 10.2 cm x 18.3 cm)
Weight ....................................................................................4.8 lbs. (2.18 kg)
Electrical
Requirements 3655A ............................................1.4 amps, 240 VAC (±10%) 50 Hz
3655SE & 3655U ..............................1.4 amps, 230 VAC (±10%) 50 Hz
Sound Level.............................................................................................56 dBA
Power Consumption ...............................................................160 watts maximum
Max. Compressor Pressure..........................................35 psig or greater* (241 kPa)
Compressor Free Air Flow ...........................................................8 lpm or greater*
Operating Temperature Range .......................................................+40° to +104°F
(+5 to +40°C)
Operating Humidity ......................................................up to 95% non-condensing
Storage/Transport Temperature Range ............................................-40° to +158°F
(-40° to +70°C)
Storage/Transport Humidity ..........................................up to 95% non-condensing
Supplied Nebulizer Capacity .................................................................6 ml (cc)
Supplied Nebulizer Nebulization Rate .....................................0.15 ml/min or greater*
Supplied Nebulizer MMAD .......................................................5 microns or less**
*Conditions may vary based on altitude above sea level, barometric pressure and temperature.
**Value determined with minimum flow rate through the nebulizer (20° C, sea level).
This product complies with the following electromagnetic compatibility standard: IEC
60601-1-2:2nd Edition
Equipment Classifications:
Protection against electric shock:................................................................Class II
Degree of protection against electric shock: .................................................Type BF
Equipment not suitable for use in the presence of flammable anaesthetic mixture with air or
with oxygen or nitrous oxide
Mode of operation:.................................................................Continuous operation
FIVE-YEAR LIMITED WARRANTY ON COMPRESSOR PARTS
All DeVilbiss Compact Compressor models are warranted to be free from defective workman-
ship and material for a period of five years from the date of purchase. Any defective part(s)
will be repaired or replaced at Sunrise's option if the unit has not been tampered with or
used improperly during that period. Make certain that any malfunction is not due to inade-
quate cleaning or failure to follow the instructions. If repair is necessary, contact your
authorized Sunrise provider or Sunrise Service Department at 800-333-4000 (814-443-4881)
(Europe 44-138-444-6688) for instructions. NOTE— This warranty does not cover providing
a loaner compressor, compensating for costs incurred in compressor rental while said unit is
under repair, or costs for labor incurred in repairing or replacing defective part(s).
SE-655

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Pulmo-aide 3655sePulmo-aide 3655u

Tabla de contenido